510(k) Report

510(k) · Cleared

Cleared

ClearCheck (RADCC V2.7)

K253962510(k) TraditionalCleared Apr 3, 2026113-day reviewClass II21 CFR 892.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Radformation, Inc. · IYE Accelerator, Linear, Medical

Cleared on Apr 3, 2026 as substantially equivalent to K220583 (Radformation, Inc., 2022) after a 113-day review. Its family tree reaches back 14 generations to 1996.

Decided
Apr 3, 2026
Review
113 days
Class
Class II
Product code
IYE
Recalls
None
Predicates
1

Its longest line of descent runs back 14 generations to K954874 (1996). 94 ancestors in all, the oldest K871859 (1987). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2017: 1 other ancestor2016: 1 other ancestor2014: 1 other ancestor2012: 1 other ancestor2009: 2 other ancestors2008: 1 other ancestor2007: 3 other ancestors2006: 3 other ancestors2004: 7 other ancestors2001: 10 other ancestors2000: 5 other ancestors1998: 4 other ancestors2005: 2 other ancestors2003: 3 other ancestors1999: 2 other ancestors1997: 5 other ancestors1995: 6 other ancestors2002: 3 other ancestors1994: 2 other ancestors1993: 2 other ancestors1992: 3 other ancestors1991: 5 other ancestors1987: 1 other ancestor1990: 2 other ancestors1988: 1 other ancestor1996: 3 other ancestors1989: 1 other ancestorReference device: K200608 · Eclipse Treatment Planning System v16.0 · Varian Medical Systems, Inc. · 2020Reference device: K242729 · AutoContour (Model RADAC V4) · Radformation, Inc. · 2024K954874 · Spectef Protocol · GE Medical Systems · 1996K980914 · Emory Cardiac Tool Box · Emory University · 1998K992450 · Emory Cardiac Toolbox* 2.0 Executing on Nuclear Medicine Computers · Emory University · 1999K014033 · Emory Cardiac Toolbox 2.1 Executing on Nuclear Medicine Computers · Syntermed, Inc. · 2002K040141 · Emory Cardiac Toolbox Version 2.6 · Syntermed, Inc. · 2004K052379 · Mim 3.5 (Circa) · Mimvista Corp. · 2005×2: 2 generations cleared close together, K060816 (2006), K062163 (2006) K103785 · Mobile Mim · Mim Software, Inc. · 2011K112930 · Mobile Mim · Mim Software, Inc. · 2011K123230 · Mosaiq Oncology Information System · Impac Medical Systems, Inc. · 2012 · recalledK142142 · Quality Reports · Sun Nuclear Corporation · 2014K162468 · ClearCheck · Radformation · 2016K220583 · ClearCheck Model RADCC V2 · Radformation, Inc. · 20221990200020102020
  1. Root · 14 generations backK954874 Spectef ProtocolGE Medical Systems · 1996
  2. 10 generations between
  3. 3 generations backK142142 Quality ReportsSun Nuclear Corporation · 2014
  4. 2 generations backK162468 ClearCheckRadformation · 2016
  5. 1 generation backK220583 ClearCheck Model RADCC V2Radformation, Inc. · 2022
  6. This deviceK253962 ClearCheck (RADCC V2.7)Radformation, Inc. · 2026
Show all 14 generations
  1. Root · 14 generations backK954874 Spectef ProtocolGE Medical Systems · 1996
  2. 13 generations backK980914 Emory Cardiac Tool BoxEmory University · 1998
  3. 12 generations backK992450 Emory Cardiac Toolbox* 2.0 Executing on Nuclear Medicine ComputersEmory University · 1999
  4. 11 generations backK014033 Emory Cardiac Toolbox 2.1 Executing on Nuclear Medicine ComputersSyntermed, Inc. · 2002
  5. 10 generations backK040141 Emory Cardiac Toolbox Version 2.6Syntermed, Inc. · 2004
  6. 9 generations backK052379 Mim 3.5 (Circa)Mimvista Corp. · 2005
  7. 8 generations backK060816 Mim 4.0 (NeuroMimvista Corp. · 2006 · Recalled
  8. 7 generations backK062163 MimviewerMimvista Corp. · 2006
  9. 6 generations backK103785 Mobile MimMim Software, Inc. · 2011
  10. 5 generations backK112930 Mobile MimMim Software, Inc. · 2011
  11. 4 generations backK123230 Mosaiq Oncology Information SystemImpac Medical Systems, Inc. · 2012 · Recalled
  12. 3 generations backK142142 Quality ReportsSun Nuclear Corporation · 2014
  13. 2 generations backK162468 ClearCheckRadformation · 2016
  14. 1 generation backK220583 ClearCheck Model RADCC V2Radformation, Inc. · 2022
  15. This deviceK253962 ClearCheck (RADCC V2.7)Radformation, Inc. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K954874Spectef ProtocolGE Medical Systems1996—
−13K980914Emory Cardiac Tool BoxEmory University1998—
−12K992450Emory Cardiac Toolbox* 2.0 Executing on Nuclear Medicine ComputersEmory University1999—
−11K014033Emory Cardiac Toolbox 2.1 Executing on Nuclear Medicine ComputersSyntermed, Inc.2002—
−10K040141Emory Cardiac Toolbox Version 2.6Syntermed, Inc.2004—
−9K052379Mim 3.5 (Circa)Mimvista Corp.2005—
−8K060816Mim 4.0 (NeuroMimvista Corp.20061
−7K062163MimviewerMimvista Corp.2006—
−6K103785Mobile MimMim Software, Inc.2011—
−5K112930Mobile MimMim Software, Inc.2011—
−4K123230Mosaiq Oncology Information SystemImpac Medical Systems, Inc.20127
−3K142142Quality ReportsSun Nuclear Corporation2014—
−2K162468ClearCheckRadformation2016—
−1K220583ClearCheck Model RADCC V2Radformation, Inc.2022—
0 (this device)K253962ClearCheck (RADCC V2.7)Radformation, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198810
198910
199020
199150
199230
199320
199420
199560
199630
199750
199840
199920
200050
2001100
200230
200330
200470
200520
200630
200730
200810
200920
201210
201410
201610
201710
FIG. 1 — Lineage of K253962, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYE device

  1. #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K220583ClearCheck Model RADCC V2
Summary page 6
…edicate Device and Reference Device Information Predicate Device ClearCheck (RADCC V2.7) (Subject Device) makes use of its prior submission - ClearCheck Model RADCC V2 (K220583) - as the primary Predicate Device. The Indications for Use, patient population, functionality, and technical components of this…
Radformation, Inc.2022—
†K200608Eclipse Treatment Planning System v16.0Varian Medical Systems, Inc.2020—
†K242729AutoContour (Model RADAC V4)Radformation, Inc.2024—

Also cleared against K220583: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 9 companies; a new generation was cleared every 2.0 years on median.
  • 22 of the 94 ancestors have a recall of any class.
  • 1 other device also cites its predicate K220583.

How does its category compare?

All IYE devices

IYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · IYE

12in 2025

2007: 232008: 142009: 202010: 232011: 112012: 282013: 182014: 202015: 202016: 212017: 232018: 212019: 192020: 202021: 192022: 122023: 182024: 92025: 122026 (partial year): 14
2007high 28 (2012) · low 9 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYE

170in 2025

2007: 44 days median2008: 69 days median2009: 63 days median2010: 74 days median2011: 94 days median2012: 106 days median2013: 88 days median2014: 100 days median2015: 108 days median2016: 97 days median2017: 94 days median2018: 58 days median2019: 83 days median2020: 67 days median2021: 86 days median2022: 172 days median2023: 129 days median2024: 239 days median2025: 170 days median2026 (partial year): 120 days median
2007high 239 (2024) · low 44 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYE

1in 2025

2007: 782008: 492009: 222010: 272011: 732012: 202013: 112014: 142015: 82016: 72017: 72018: 72019: 22020: 42021: 52022: 32023: 72024: 12025: 12026 (partial year): 4
2007high 78 (2007) · low 1 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IYE

101in 2025

2007: 1552008: 1142009: 1742010: 2462011: 2802012: 1282013: 962014: 1242015: 1002016: 972017: 1252018: 852019: 912020: 742021: 682022: 662023: 1282024: 812025: 101
2007high 280 (2011) · low 66 (2022)2025

MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007234478155
2008146949114
2009206322174
2010237427246
2011119473280
20122810620128
201318881196
20142010014124
2015201088100
20162197797
201723947125
20182158785
20191983291
20202067474
20211986568
202212172366
2023181297128
20249239181
2025121701101
2026141204—

What is it indicated for?

ClearCheck is intended to assist radiation therapy professionals in generating and assessing the quality of radiotherapy treatment plans. ClearCheck is also intended to assist radiation treatment planners in predicting when a treatment plan might result in a collision between the treatment machine and the patient or support structures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253962: ClearCheck (RADCC V2.7).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253962

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026