510(k) Report

510(k) · Cleared

Cleared

SAYA 86 Radial Access Guide Catheter

K254178510(k) TraditionalCleared May 11, 2026139-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Asahi Intecc Co., Ltd. · QJP Catheter, Percutaneous, Neurovasculature

Cleared on May 11, 2026 as substantially equivalent to K241388 (Micro Therapeutics, Inc. d/b/a ev3 Neurovascular, 2025) after a 139-day review. Its family tree reaches back 10 generations to 2001.

Decided
May 11, 2026
Review
139 days
Class
Class II
Product code
QJP
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K010954 (2001). 25 ancestors in all, the oldest K925813 (1994). No later device cites it as a predicate yet.

  1. Root · 10 generations backK010954 Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc. · 2001 · Recalled
  2. 6 generations between
  3. 3 generations backK150366 SOFIA 6F CatheterMicroVention, Inc. · 2015
  4. 2 generations backK201682 RIST Radial Access CatheterRist Neurovascular, Inc. · 2020
  5. 1 generation backK241388 Rist 079 Radial Access Guide Catheter; Rist 071 Radial Access Guide…Micro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2025
  6. This deviceK254178 SAYA 86 Radial Access Guide CatheterAsahi Intecc Co., Ltd. · 2026
Show all 10 generations
  1. Root · 10 generations backK010954 Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc. · 2001 · Recalled
  2. 9 generations backK021899 Concentric Balloon Guide Catheter, Model 90072Concentric Medical, Inc. · 2002 · Recalled
  3. 8 generations backK053491 Penumbra Balloon Guide Catheter, Model 7.5FPenumbra, Inc. · 2006
  4. 7 generations backK070970 Neuron Support Catheter System, Model 5F/6FPenumbra, Inc. · 2007 · Recalled
  5. 6 generations backK082385 Chaperon Guiding CatheterMicroVention, Inc. · 2008
  6. 5 generations backK131482 Sofia Distal Access CatheterMicroVention, Inc. · 2013
  7. 4 generations backK142014 Sofia Distal Access CatheterMicroVention, Inc. · 2014
  8. 3 generations backK150366 SOFIA 6F CatheterMicroVention, Inc. · 2015
  9. 2 generations backK201682 RIST Radial Access CatheterRist Neurovascular, Inc. · 2020
  10. 1 generation backK241388 Rist 079 Radial Access Guide Catheter; Rist 071 Radial Access Guide…Micro Therapeutics, Inc. d/b/a ev3 Neurovascular · 2025
  11. This deviceK254178 SAYA 86 Radial Access Guide CatheterAsahi Intecc Co., Ltd. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K010954Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc.20011
−9K021899Concentric Balloon Guide Catheter, Model 90072Concentric Medical, Inc.20021
−8K053491Penumbra Balloon Guide Catheter, Model 7.5FPenumbra, Inc.2006—
−7K070970Neuron Support Catheter System, Model 5F/6FPenumbra, Inc.20071
−6K082385Chaperon Guiding CatheterMicroVention, Inc.2008—
−5K131482Sofia Distal Access CatheterMicroVention, Inc.2013—
−4K142014Sofia Distal Access CatheterMicroVention, Inc.2014—
−3K150366SOFIA 6F CatheterMicroVention, Inc.2015—
−2K201682RIST Radial Access CatheterRist Neurovascular, Inc.2020—
−1K241388Rist 079 Radial Access Guide Catheter; Rist 071 Radial Access Guide Catheter…Micro Therapeutics, Inc. d/b/a ev3 Neurovascular2025—
0 (this device)K254178SAYA 86 Radial Access Guide CatheterAsahi Intecc Co., Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199610
200010
200120
200830
201110
201210
201510
201610
201910
202010
202110
FIG. 1 — Lineage of K254178, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QJP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QJP device

  1. #1 K212838 Benchmark Intracranial Access Systemscore 16.9 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K241388Rist 079 Radial Access Guide Catheter; Rist 071 Radial Access Guide Catheter; Rist…
Summary page 5
…ct Code: QJP- Percutaneous Catheter, Neurovasculature Predicate Device: Rist™ 079 Radial Access Guide Catheter (K241388) Reference Device: FUBUKI XF Neurovascular Long Sheath (K213589) ASAHI INTECC CO., LTD.…
Micro Therapeutics, Inc. d/b/a ev3 Neurovascular2025—
†K213589FUBUKI XF Neurovascular Long SheathAsahi Intecc Co., Ltd.2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 6 companies; a new generation was cleared every 1.4 years on median.
  • 8 of the 25 ancestors have a recall of any class.

How does its category compare?

All QJP devices

QJP Catheter, Percutaneous, Neurovasculature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · QJP

22so far in 2026, the most since 2007

2020: 92021: 122022: 142023: 142024: 182025: 142026 (partial year): 22
2007high 22 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QJP

116in 2025

2020: 72 days median2021: 139 days median2022: 206 days median2023: 184 days median2024: 188 days median2025: 116 days median2026 (partial year): 141 days median
2007high 206 (2022) · low 72 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QJP

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QJP

688in 2025

2020: 162021: 292022: 302023: 752024: 1302025: 688
2007high 688 (2025) · low 0 (2007)2025

MAUDE reports naming product code QJP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
2020972016
202112139029
202214206030
202314184075
2024181881130
2025141160688
2026221410—

What is it indicated for?

The SAYA 86 Radial Access Guide Catheter is indicated for the introduction of interventional devices into the neurovasculature.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K254178: SAYA 86 Radial Access Guide Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K254178

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026