510(k) Report

510(k) · Cleared

Cleared

Aevumed FENIX Suture Anchor

K254306510(k) TraditionalCleared Mar 4, 202663-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aevumed, Inc. · MBI Fastener, Fixation, Nondegradable, Soft Tissue

Cleared on Mar 4, 2026 as substantially equivalent to K181769 (Arthrex, Inc., 2018) and 2 other predicates after a 63-day review. Its family tree reaches back 10 generations to 1996.

Decided
Mar 4, 2026
Review
63 days
Class
Class II
Product code
MBI
Recalls
None
Predicates
3

Its longest line of descent runs back 10 generations to K961555 (1996). 21 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 10 generations backK961555 Acufex Tag Bioabsorbable AnchorsAcufex Microsurgical, Inc. · 1996
  2. 6 generations between
  3. 3 generations backK140476 Arthrex Fibertak Suture AnchorArthrex, Inc. · 2014
  4. 2 generations backK151230 Arthrex FiberTak AnchorsArthrex, Inc. · 2015
  5. 1 generation backK181769 Arthrex FiberTak Suture AnchorArthrex, Inc. · 2018
  6. This deviceK254306 Aevumed FENIX Suture AnchorAevumed, Inc. · 2026
Show all 10 generations
  1. Root · 10 generations backK961555 Acufex Tag Bioabsorbable AnchorsAcufex Microsurgical, Inc. · 1996
  2. 9 generations backK031685 Tag Rod Bioraptor Suture Anchor 7209317, 7209318Smith & Nephew, Inc. · 2003 · Recalled
  3. 8 generations backK053344 Bioraptor Suture Anchor, Twinfix 2.8 MM Suture Anchor, Twinfix 3.5…Smith & Nephew, Inc. · 2006
  4. 7 generations backK061863 Arthrex Corkscrew Suture Anchor, Tak, and Pushlock FamilyArthrex, Inc. · 2006
  5. 6 generations backK071177 Arthrex Bio- Composite Suture Anchors: Bio-Composite Pushlock…Arthrex, Inc. · 2007
  6. 5 generations backK091844 Arthrex Bio-Composite Suturetak AnchorsArthrex, Inc. · 2009
  7. 4 generations backK112237 Microsuture AnchorsArthrex, Inc. · 2011
  8. 3 generations backK140476 Arthrex Fibertak Suture AnchorArthrex, Inc. · 2014
  9. 2 generations backK151230 Arthrex FiberTak AnchorsArthrex, Inc. · 2015
  10. 1 generation backK181769 Arthrex FiberTak Suture AnchorArthrex, Inc. · 2018
  11. This deviceK254306 Aevumed FENIX Suture AnchorAevumed, Inc. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K961555Acufex Tag Bioabsorbable AnchorsAcufex Microsurgical, Inc.1996—
−9K031685Tag Rod Bioraptor Suture Anchor 7209317, 7209318Smith & Nephew, Inc.20035
−8K053344Bioraptor Suture Anchor, Twinfix 2.8 MM Suture Anchor, Twinfix 3.5 MM Suture…Smith & Nephew, Inc.2006—
−7K061863Arthrex Corkscrew Suture Anchor, Tak, and Pushlock FamilyArthrex, Inc.2006—
−6K071177Arthrex Bio- Composite Suture Anchors: Bio-Composite Pushlock, Bio-Composite…Arthrex, Inc.2007—
−5K091844Arthrex Bio-Composite Suturetak AnchorsArthrex, Inc.2009—
−4K112237Microsuture AnchorsArthrex, Inc.2011—
−3K140476Arthrex Fibertak Suture AnchorArthrex, Inc.2014—
−2K151230Arthrex FiberTak AnchorsArthrex, Inc.2015—
−1K181769Arthrex FiberTak Suture AnchorArthrex, Inc.2018—
0 (this device)K254306Aevumed FENIX Suture AnchorAevumed, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
200010
200110
200410
200510
200620
201110
201410
201810
202310
FIG. 1 — Lineage of K254306, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MBI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MBI device

  1. #1 K203268 Arthrex FiberTak Suture Anchorscore 21.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K181769Arthrex FiberTak Suture Anchor
Summary page 5
…eners, classified as CLASSIFICATION: Class II, product code MBI Regulation 21 CFR 888.3040 PRIMARY PREDICATE Arthrex FiberTak Suture Anchor, 510(k) number K181769 DEVICE: ADDITIONAL PREDICATE DEVICE: Aevumed PHANTOMTM Suture Anchor, 510(k) number K180464 Aevumed…
Arthrex, Inc.2018—
*K180464AEVUMED PHANTOM Suture Anchors
Summary page 5
…PRIMARY PREDICATE Arthrex FiberTak Suture Anchor, 510(k) number K181769 DEVICE: ADDITIONAL PREDICATE DEVICE: Aevumed PHANTOMTM Suture Anchor, 510(k) number K180464 Aevumed RAPIDTM Suture Anchors, 510(k) number K223878 DEVICE DESCRIPTION: The Aevumed FENIXTM Sutures…
Aevumed, Inc.2018—
*K223878Aevumed RAPID Suture Anchors
Summary page 5
…9 DEVICE: ADDITIONAL PREDICATE DEVICE: Aevumed PHANTOMTM Suture Anchor, 510(k) number K180464 Aevumed RAPIDTM Suture Anchors, 510(k) number K223878 DEVICE DESCRIPTION: The Aevumed FENIXTM Sutures Anchor is a suture anchor manufactured from HS FiberT…
Aevumed, Inc.2023—

Also cleared against K181769: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 4 companies; a new generation was cleared every 2.7 years on median.
  • 2 of the 21 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K181769.

How does its category compare?

All MBI devices

MBI Fastener, Fixation, Nondegradable, Soft Tissue: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · MBI

27in 2025

2007: 162008: 102009: 192010: 172011: 302012: 242013: 312014: 232015: 232016: 172017: 172018: 162019: 312020: 352021: 182022: 192023: 522024: 222025: 272026 (partial year): 30
2007high 52 (2023) · low 10 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MBI

58in 2025

2007: 80 days median2008: 69 days median2009: 82 days median2010: 76 days median2011: 75 days median2012: 94 days median2013: 100 days median2014: 101 days median2015: 85 days median2016: 94 days median2017: 70 days median2018: 91 days median2019: 90 days median2020: 83 days median2021: 107 days median2022: 64 days median2023: 57 days median2024: 30 days median2025: 58 days median2026 (partial year): 63 days median
2007high 107 (2021) · low 30 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MBI

1in 2025

2007: 242008: 62009: 22010: 32011: 232012: 62013: 22017: 42018: 22020: 12023: 12024: 12025: 1
2007high 24 (2007) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MBI

3,826in 2025

2007: 2402008: 3382009: 3552010: 2912011: 3282012: 3712013: 4422014: 5042015: 5072016: 7952017: 6752018: 1,0722019: 1,3032020: 1,4542021: 1,8902022: 1,5912023: 2,5032024: 3,7792025: 3,826
2007high 3,826 (2025) · low 240 (2007)2025

MAUDE reports naming product code MBI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007168024240
200810696338
200919822355
201017763291
2011307523328
201224946371
2013311002442
2014231010504
201523850507
201617940795
201717704675
2018169121,072
2019319001,303
2020358311,454
20211810701,890
2022196401,591
2023525712,503
2024223013,779
2025275813,826
202630630—

What is it indicated for?

The Aevumed FENIX™ Suture Anchors are intended to be used for suture or tissue fixation in the foot, ankle, knee, hand, wrist, elbow, shoulder, and hip. Specific indications are listed below: Shoulder: Rotator Cuff Repair, Ban kart Repair, SLAP Lesion Repair, Biceps Tenodesis, Acromio-Clabicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction FooUAnkle: Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair…

Read the full statement (138 words)

The Aevumed FENIX™ Suture Anchors are intended to be used for suture or tissue fixation in the foot, ankle, knee, hand, wrist, elbow, shoulder, and hip. Specific indications are listed below:

Shoulder: Rotator Cuff Repair, Ban kart Repair, SLAP Lesion Repair, Biceps Tenodesis, Acromio-Clabicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction

FooUAnkle: Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair, Metatarsal Ligament Repair, Hallux Valgus Reconstruction, Digital Tendon Transfers, Mid-foot Reconstruction

Knee: Medial Collateral Ligament Repair, Lateral Collateral Ligament Repair, Patellar Tendon Repair, Posterior Oblique Ligament Repair, lliotibial Band Tenodesis

Hand/Wrist: Scapholunate Ligament Reconstruction, Carpal Ligament Reconstruction, Repair/ Reconstruction of Collateral Ligaments, Repair of Flexor and Extensor Tendons at the PIP, DIP, and MCP joints for all Digits, Digital Tendon Transfers

Elbow: Biceps Tendon Reattachment, Ulnar or Radial Collateral Ligament Reconstruction

Hip: Capsular repair, Acetabular Labral Repair

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K254306: Aevumed FENIX Suture Anchor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K254306

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026