510(k) Report

510(k) · Cleared

Cleared

OrthoEasy Pal; OrthoEasy Pal Long Neck

K260268510(k) TraditionalCleared May 19, 2026111-day reviewClass II21 CFR 872.3640

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bernhard Förster GmbH (Bernhard Foerster Ltd.) · OAT Implant, Endosseous, Orthodontic

Cleared on May 19, 2026 as substantially equivalent to K110275 (Forestadent Bernhard Forster GmbH, 2011) after a 111-day review. Its family tree reaches back 7 generations to 1990.

Decided
May 19, 2026
Review
111 days
Class
Class II
Product code
OAT
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K894844 (1990). 18 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK894844 Bonefit Implant System Accessories & InstrumentsStraumann Institute, Ltd. · 1990
  2. 6 generations backK973353 Bonding BaseStraumann USA · 1997
  3. 5 generations backK982509 Ortho Implant and AccessoriesStraumann USA · 1998
  4. 4 generations backK031936 Osteomed Orthodontic Screw SystemOsteomed LP · 2004
  5. 3 generations backK033767 Dual Top Anchor System ScrewsJeil Medical Corporation · 2004
  6. 2 generations backK062733 Tomas Pin SD 6, 8, and 10 MMDentaurum · 2006
  7. 1 generation backK110275 Ortho Easy PinForestadent Bernhard Forster GmbH · 2011
  8. This deviceK260268 OrthoEasy Pal; OrthoEasy Pal Long NeckBernhard Förster GmbH (Bernhard Foerster Ltd.) · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K894844Bonefit Implant System Accessories & InstrumentsStraumann Institute, Ltd.1990—
−6K973353Bonding BaseStraumann USA1997—
−5K982509Ortho Implant and AccessoriesStraumann USA1998—
−4K031936Osteomed Orthodontic Screw SystemOsteomed LP2004—
−3K033767Dual Top Anchor System ScrewsJeil Medical Corporation2004—
−2K062733Tomas Pin SD 6, 8, and 10 MMDentaurum2006—
−1K110275Ortho Easy PinForestadent Bernhard Forster GmbH2011—
0 (this device)K260268OrthoEasy Pal; OrthoEasy Pal Long NeckBernhard Förster GmbH (Bernhard Foerster Ltd.)2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199330
199420
199520
199720
199810
200010
FIG. 1 — Lineage of K260268, 1990–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OAT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OAT device

  1. #1 K242944 Leone Orthodontic Implant TAD (Temporary…score 12.2 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110275Ortho Easy Pin
Summary page 5
…Regulation Number 872.3640 Product Code OAT IV) Predicate Device 510(k) K110275 Applicant Bernhard Förster GmbH (Bernhard Foerster Ltd.) Trade Name…
Forestadent Bernhard Forster GmbH2011—
†K110392PSM Lomas / Benefit ScrewsPsm Medical Solutions2011—
†K202691Ortholock Anchorage DevicesCraniofacial Technologies, Inc.2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 36 years and passes through 7 companies; a new generation was cleared every 4.6 years on median.
  • None of the 18 ancestors has a recall.

How does its category compare?

All OAT devices

OAT Implant, Endosseous, Orthodontic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · OAT

1in 2025

2007: 62008: 32009: 22010: 22011: 52012: 12013: 22014: 12015: 12016: 22017: 12018: 12019: 22020: 32021: 42022: 22023: 12024: 22025: 12026 (partial year): 1
2007high 6 (2007) · low 1 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OAT

224in 2021

2007: 104 days median2008: 94 days median2011: 152 days median2020: 289 days median2021: 224 days median
2007high 289 (2020) · low 94 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OAT

2in 2007

2007: 2
2007high 2 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OAT

5in 2025

2007: 22010: 12012: 32013: 22014: 42015: 282016: 122018: 12020: 382021: 682022: 842023: 782024: 92025: 5
2007high 84 (2022) · low 0 (2008)2025

MAUDE reports naming product code OAT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007610422
200839400
20092—00
20102—01
2011515200
20121—03
20132—02
20141—04
20151—028
20162—012
20171—00
20181—01
20192—00
20203289038
20214224068
20222—084
20231—078
20242—09
20251—05
20261—0—

What is it indicated for?

FORESTADENT OrthoEasy® anchorage screws are intended to provide a fixed anchorage point for the attachment of orthodontic appliances to facilitate the orthodontic movement of teeth in adolescents greater than 12 years of age and adults. It is used temporarily and is removed after orthodontic treatment has been completed. The screws are intended for single use only.

The device is not intended for palatal expansion or for use as a prosthodontic or dental implant component.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K260268: OrthoEasy Pal; OrthoEasy Pal Long Neck.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K260268

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026