510(k) · Cleared
ClearedTENS 7000 Rechargeable 4 Channel (TENS 7000H)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shenzhen Dongdixin Technology Co., Ltd. · NUH Stimulator, Nerve, Transcutaneous, Over-The-Counter
Cleared on Jun 26, 2026 after a 137-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Jun 26, 2026
- Review
- 137 days
- Class
- Class II
- Product code
- NUH
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NUH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NUH device
- #1 K190783 Health Expert Electronic Stimulator (model…score 15.8 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All NUH devicesNUH Stimulator, Nerve, Transcutaneous, Over-The-Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · NUH
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NUH
119in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NUH
No recall names NUH since 2007.
Adverse event reports per year · NUH
7in 2025
MAUDE reports naming product code NUH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 161 | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 3 | 148 | 0 | 0 |
| 2011 | 6 | 231 | 0 | 0 |
| 2012 | 6 | 170 | 0 | 0 |
| 2013 | 10 | 189 | 0 | 1 |
| 2014 | 16 | 212 | 0 | 9 |
| 2015 | 14 | 198 | 0 | 11 |
| 2016 | 13 | 145 | 0 | 13 |
| 2017 | 17 | 155 | 0 | 21 |
| 2018 | 16 | 121 | 0 | 18 |
| 2019 | 19 | 213 | 0 | 5 |
| 2020 | 14 | 147 | 0 | 8 |
| 2021 | 14 | 198 | 0 | 7 |
| 2022 | 20 | 103 | 0 | 2 |
| 2023 | 15 | 127 | 0 | 4 |
| 2024 | 20 | 90 | 0 | 7 |
| 2025 | 15 | 119 | 0 | 7 |
| 2026 | 5 | 137 | 0 | — |
What is it indicated for?
TENS: The device is designed to be used for:
-Temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arm), lower extremities (leg), abdomen and bottom due to strain from exercise or normal household work activities.
-The symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis.
EMS: The device is designed to be used for stimulate healthy muscles in order to improve and facilitate muscle performance.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K260412 · printed Nov 6, 2026
Cite this page
510(k) Report. “K260412: TENS 7000 Rechargeable 4 Channel (TENS 7000H).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K260412
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded Oct 30, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Page last updated Nov 3, 2026