510(k) Report

510(k) · Cleared

Cleared

RIVOS™ EUS Access Device (M00553900)

K260428510(k) TraditionalCleared Jun 17, 2026127-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corporation · ODG Endoscopic Ultrasound System, Gastroenterology-Urology

Cleared on Jun 17, 2026 as substantially equivalent to K092359 (Cook Ireland, Ltd., 2009) and 1 other predicate after a 127-day review. Its family tree reaches back 6 generations to 1995.

Decided
Jun 17, 2026
Review
127 days
Class
Class II
Product code
ODG
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K935844 (1995). 13 ancestors in all, the oldest K934356 (1994). No later device cites it as a predicate yet.

  1. Root · 6 generations backK935844 Gip/Medi-Globe Needle System for Ultrasonic FnaMedi-Globe Corp. · 1995
  2. 5 generations backK990220 Modification of Gip/Medi-Globe Ultrasound Needle SystemMedi-Globe Corp. · 1999
  3. 4 generations backK051247 Sonotip II Ultrasound Needle SystemMedi-Globe Corp. · 2005
  4. 3 generations backK070129 Sonotip II Ultrasound Needle SystemMedi-Globe Corporation · 2007
  5. 2 generations backK083330 Echotip Ultra Ultrasound NeedleCook Endoscopy · 2009
  6. 1 generation backK092359 Echo Tip Ultra High Definition Ultrasound Access Needle, Model…Cook Ireland, Ltd. · 2009 · Recalled
  7. This deviceK260428 RIVOS™ EUS Access Device (M00553900)Boston Scientific Corporation · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K935844Gip/Medi-Globe Needle System for Ultrasonic FnaMedi-Globe Corp.1995—
−5K990220Modification of Gip/Medi-Globe Ultrasound Needle SystemMedi-Globe Corp.1999—
−4K051247Sonotip II Ultrasound Needle SystemMedi-Globe Corp.2005—
−3K070129Sonotip II Ultrasound Needle SystemMedi-Globe Corporation2007—
−2K083330Echotip Ultra Ultrasound NeedleCook Endoscopy2009—
−1K092359Echo Tip Ultra High Definition Ultrasound Access Needle, Model: Echo-HD-19ACook Ireland, Ltd.20091
0 (this device)K260428RIVOS™ EUS Access Device (M00553900)Boston Scientific Corporation2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199730
200010
200110
200210
FIG. 1 — Lineage of K260428, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODG device

  1. #1 K251859 EVIS EUS Ultrasound Gastrointestinal…score 14.0 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K092359Echo Tip Ultra High Definition Ultrasound Access Needle, Model: Echo-HD-19A
Summary page 6
…K260428 Page 2 of 6 Clearance Number: K092359 Regulation Number: 876.1075 Product Code: FCG Classification: Class II…
Cook Ireland, Ltd.20091
*K022595Wilson-Cook Cystotome
Summary page 6
…Classification Name without accessories) Manufacturer: Cook Medical LLC Clearance Number: K022595 Regulation Number: 876.4300 Product Code: KNS Classification: Class II…
Wilson-Cook Medical, Inc.2002—

Also cleared against K092359: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 5 companies; a new generation was cleared every 4.1 years on median.
  • 2 of the 13 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K092359.

How does its category compare?

All ODG devices

ODG Endoscopic Ultrasound System, Gastroenterology-Urology: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · ODG

2in 2025

2009: 22011: 22013: 22014: 12016: 12017: 42018: 32019: 12020: 22021: 12022: 42023: 12024: 12025: 22026 (partial year): 2
2007high 4 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODG

71in 2022

2017: 75 days median2018: 30 days median2022: 71 days median
2007high 75 (2017) · low 30 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODG

4in 2020

2020: 42026 (partial year): 4
2007high 4 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODG

3,569in 2025

2008: 12009: 32010: 22011: 132012: 62013: 22014: 12015: 112016: 502017: 822018: 662019: 962020: 4452021: 1,2342022: 1,8322023: 2,0782024: 1,9042025: 3,569
2007high 3,569 (2025) · low 0 (2007)2025

MAUDE reports naming product code ODG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20092—03
20100—02
20112—013
20120—06
20132—02
20141—01
20150—011
20161—050
2017475082
2018330066
20191—096
20202—4445
20211—01,234
202247101,832
20231—02,078
20241—01,904
20252—03,569
20262—4—

What is it indicated for?

The device is used to access and electrosurgically puncture the transgastric or transduodenal wall into the following: the intra- or extrahepatic bile ducts, or a pancreatic pseudocyst. The device is intended for use through the accessory channel of an ultrasound endoscope.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K260428: RIVOS™ EUS Access Device (M00553900).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K260428

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026