Stabilix, LLC · IYE Accelerator, Linear, Medical
Cleared on May 8, 2026 as substantially equivalent to K960338 (Elekta Instrument AB, 1996) after a 58-day review. Its family tree reaches back 2 generations to 1994.
- Decided
- May 8, 2026
- Review
- 58 days
- Class
- Class II
- Product code
- IYE
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K935300 (1994). 3 ancestors in all. No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K935300 | Vac-Lok Immobilization System | Medtec, Inc. | 1994 | — |
| −1 | K960338 | Stereotactic Body Frame | Elekta Instrument AB | 1996 | — |
| 0 (this device) | K260792 | AerFrame Patient Immobilization System (AFPIS) | Stabilix, LLC | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYE device
- #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K960338 | Stereotactic Body FrameSummary page 5…dicate Devices 21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K960338 Stereotactic Body Frame IYE… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 32 years and passes through 3 companies; a new generation was cleared every 30.0 years on median.
- None of the 3 ancestors has a recall.
- 4 other devices also cite its predicate K960338.
How does its category compare?
All IYE devicesIYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · IYE
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IYE
170in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · IYE
101in 2025
MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 23 | 44 | 78 | 155 |
| 2008 | 14 | 69 | 49 | 114 |
| 2009 | 20 | 63 | 22 | 174 |
| 2010 | 23 | 74 | 27 | 246 |
| 2011 | 11 | 94 | 73 | 280 |
| 2012 | 28 | 106 | 20 | 128 |
| 2013 | 18 | 88 | 11 | 96 |
| 2014 | 20 | 100 | 14 | 124 |
| 2015 | 20 | 108 | 8 | 100 |
| 2016 | 21 | 97 | 7 | 97 |
| 2017 | 23 | 94 | 7 | 125 |
| 2018 | 21 | 58 | 7 | 85 |
| 2019 | 19 | 83 | 2 | 91 |
| 2020 | 20 | 67 | 4 | 74 |
| 2021 | 19 | 86 | 5 | 68 |
| 2022 | 12 | 172 | 3 | 66 |
| 2023 | 18 | 129 | 7 | 128 |
| 2024 | 9 | 239 | 1 | 81 |
| 2025 | 12 | 170 | 1 | 101 |
| 2026 | 14 | 120 | 4 | — |
What is it indicated for?
Indications for Use (AerFrame™ Patient Immobilization System) The AerFrame™ Patient Immobilization System is indicated for use to aid in patient positioning and immobilization during diagnostic imaging procedures (e.g., CT and MRI) and photon-based radiotherapy. When used for radiotherapy, the system is indicated for use only in conjunction with image-guided radiotherapy (IGRT) for final patient alignment. The AerFrame system is intended for use in…
Read the full statement (207 words)
Indications for Use (AerFrame™ Patient Immobilization System)
The AerFrame™ Patient Immobilization System is indicated for use to aid in patient positioning and immobilization during diagnostic imaging procedures (e.g., CT and MRI) and photon-based radiotherapy. When used for radiotherapy, the system is indicated for use only in conjunction with image-guided radiotherapy (IGRT) for final patient alignment. The AerFrame system is intended for use in professional healthcare facilities by trained clinical staff.
Intended Patient Population / Selection Criteria:
The AerFrame system is indicated for patients who require immobilization to support repeatable positioning during CT/MRI imaging and photon-based radiotherapy workflows and who can be safely accommodated within the AerFrame and the required vacuum bag immobilization system. The system is intended for use with a compatible vacuum bag system and is not indicated for use without a vacuum bag. Maximum patient weight is 300 lb (136 kg).
Contraindications / Limitations:
No specific contraindications. The AerFrame system is not indicated for patients who exceed the maximum patient weight limit (300 lb / 136 kg) or when use of the required vacuum bag is not possible. When used for radiotherapy, the AerFrame system is not indicated for use as the sole method of final patient alignment; IGRT must be used for final alignment
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K260792 · printed Nov 6, 2026
Cite this page
510(k) Report. “K260792: AerFrame Patient Immobilization System (AFPIS).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K260792
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded Oct 30, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026