510(k) Report

510(k) · Cleared

Cleared

LightningWire Transseptal Puncture System (TPS)

K261745510(k) TraditionalCleared Jun 26, 202630-day reviewClass II21 CFR 870.5175

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

ElectroWire Medical · DXF Catheter, Septostomy

Cleared on Jun 26, 2026 as substantially equivalent to K150709 (Baylis Medical Company, Inc., 2015) after a 30-day review. Its family tree reaches back 3 generations to 2002.

Decided
Jun 26, 2026
Review
30 days
Class
Class II
Product code
DXF
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K011727 (2002). 5 ancestors in all, the oldest K990284 (2001). No later device cites it as a predicate yet.

  1. Root · 3 generations backK011727 Transseptal Needle/TrocarThomas Medical Products, Inc. · 2002 · Recalled
  2. 2 generations backK073326 NRG Transseptal NeedleBaylis Medical Co., Inc. · 2008 · Recalled
  3. 1 generation backK150709 ProTrack RF Anchor WireBaylis Medical Company, Inc. · 2015 · Recalled
  4. This deviceK261745 LightningWire Transseptal Puncture System (TPS)ElectroWire Medical · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K011727Transseptal Needle/TrocarThomas Medical Products, Inc.20021
−2K073326NRG Transseptal NeedleBaylis Medical Co., Inc.20081
−1K150709ProTrack RF Anchor WireBaylis Medical Company, Inc.20151
0 (this device)K261745LightningWire Transseptal Puncture System (TPS)ElectroWire Medical2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200310
FIG. 1 — Lineage of K261745, 2002–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXF device

  1. #1 K242076 VersaCross™ RF Wirescore 14.9 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150709ProTrack RF Anchor Wire
Summary page 5
…FDA 510(k) VersaCross RF Wire Boston Scientific K150709 (formerly Protrack RF Anchor Wire) (formerly Baylis Medical) Device Description The LightningWire Transseptal Punct…
Baylis Medical Company, Inc.20151

Also cleared against K150709: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 4 companies; a new generation was cleared every 7.1 years on median.
  • 3 of the 5 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K150709.

How does its category compare?

All DXF devices

DXF Catheter, Septostomy: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · DXF

2in 2025

2008: 12015: 12019: 12021: 12022: 12023: 12024: 42025: 22026 (partial year): 3
2007high 4 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXF

83in 2024

2024: 83 days median2026 (partial year): 30 days median
2007high 83 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXF

3in 2020

2016: 12020: 3, 3 Class I
2007high 3 (2020) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · DXF

682in 2025

2007: 22008: 82009: 32010: 42011: 62012: 22013: 12014: 42015: 212016: 132017: 132018: 362019: 242020: 552021: 392022: 702023: 2862024: 3682025: 682
2007high 682 (2025) · low 1 (2013)2025

MAUDE reports naming product code DXF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20081—08
20090—03
20100—04
20110—06
20120—02
20130—01
20140—04
20151—021
20160—113
20170—013
20180—036
20191—024
20200—3 (3)55
20211—039
20221—070
20231—0286
20244830368
20252—0682
20263300—

What is it indicated for?

The LightningWire TPS is used to create an atrial septal defect in the heart, whereby various cardiovascular catheters are introduced.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K261745: LightningWire Transseptal Puncture System (TPS).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K261745

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026