510(k) · Cleared
ClearedZSAlign Cervical Interbody System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
ZSFab, Inc. · OVE Intervertebral Fusion Device With Integrated Fixation, Cervical
Cleared on Oct 2, 2026 after a 28-day review. FDA has not posted a summary or statement for it, so its predicates are not known.
- Decided
- Oct 2, 2026
- Review
- 28 days
- Class
- Class II
- Product code
- OVE
- Recalls
- None
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OVE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OVE device
- #1 K241846 E3D™-C Interbody Systemscore 32.1 · 32 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All OVE devicesOVE Intervertebral Fusion Device With Integrated Fixation, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · OVE
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OVE
105in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OVE
2in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OVE
132in 2025
MAUDE reports naming product code OVE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 4 | 131 | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 4 | 210 | 0 | 2 |
| 2011 | 8 | 139 | 0 | 19 |
| 2012 | 7 | 125 | 0 | 59 |
| 2013 | 5 | 71 | 1 | 250 |
| 2014 | 11 | 168 | 1 | 150 |
| 2015 | 12 | 113 | 1 | 173 |
| 2016 | 15 | 149 | 1 | 145 |
| 2017 | 9 | 100 | 1 | 134 |
| 2018 | 7 | 105 | 0 | 210 |
| 2019 | 7 | 87 | 0 | 169 |
| 2020 | 13 | 149 | 0 | 162 |
| 2021 | 10 | 93 | 2 | 186 |
| 2022 | 10 | 144 | 0 | 200 |
| 2023 | 16 | 97 | 0 | 148 |
| 2024 | 6 | 56 | 0 | 142 |
| 2025 | 10 | 105 | 0 | 132 |
| 2026 | 13 | 66 | 0 | — |
https://510kreport.com/device/K263113 · printed Nov 3, 2026
Cite this page
510(k) Report. “K263113: ZSAlign Cervical Interbody System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K263113
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded Oct 30, 2026
- Page last updated Nov 3, 2026