510(k) Report

510(k) · Cleared

Cleared

RF Controls

K790986510(k) TraditionalCleared Jun 28, 197934-day reviewClass I21 CFR 862.3240

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wampole Laboratories · DMR Solution, M-Nitrophenol, Specific Reagent For Cholinesterase

Cleared on Jun 28, 1979 after a 34-day review. FDA has not posted a summary or statement for it, so its predicates are not known.

Decided
Jun 28, 1979
Review
34 days
Class
Class I
Product code
DMR
Recalls
None
Predicates
0

FDA has not posted a summary or statement for it, so its predicates are not known.

FIG. 1 — Lineage of K790986Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DMR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All DMR devices

DMR Solution, M-Nitrophenol, Specific Reagent For Cholinesterase: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DMR

FDA has decided no DMR device since 2007.

Median 510(k) review, days · DMR

Too few DMR 510(k)s in any year since 2007 to give a median.

Recalls per year · DMR

No recall names DMR since 2007.

Adverse event reports per year · DMR

No MAUDE report names DMR since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—
Cite this page

510(k) Report. “K790986: RF Controls.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K790986

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Page last updated Nov 3, 2026