510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Unipor Breathing Circuit Filter

K791307510(k) TraditionalCleared Aug 3, 197918-day reviewClass II21 CFR 868.5260Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pall Biomedical Products Co. · CAH Filter, Bacterial, Breathing-Circuit

Cleared on Aug 3, 1979 after an 18-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 1 later device descends from it. It has been recalled once.

Decided
Aug 3, 1979
Review
18 days
Class
Class II
Product code
CAH
Recalls
1
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared19801990200020102020
  1. This deviceK791307 Unipor Breathing Circuit FilterPall Biomedical Products Co. · 1979
  2. Descendant · cites it directly · 0 of its ownK032716 Portex Thermovent Hepa Hme Breathing Filter with CO2 Port (Sterile…Portex, Ltd. · 2003

Most influential descendants

Showing 1 of 1 · See all
  • K032716Portex Thermovent Hepa Hme Breathing Filter with CO2 Port (Sterile and Non-Sterile)Portex, Ltd. · 2003 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K791307Unipor Breathing Circuit FilterPall Biomedical Products Co.1979—
+1K032716Portex Thermovent Hepa Hme Breathing Filter with CO2 Port (Sterile and…Portex, Ltd.2003—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K791307, 1979–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CAH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAH device

  1. #1 K251583 Ambu® Virobac II® Exhalation Filterscore 11.6 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032716Portex Thermovent Hepa Hme Breathing Filter with CO2 Port (Sterile and Non-Sterile)Portex, Ltd.20030

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 4, 2014Class IIZ-2038-2014OtherPossible leak from the filter allowing a small of amount of air to be released from the junction between the filter end cap (flat side of the filter) and the filter housing connection.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K032716 (Portex, Ltd., 2003) has gone furthest, with 0 descendants of its own.

How does its category compare?

All CAH devices

CAH Filter, Bacterial, Breathing-Circuit: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CAH

2in 2024

2007: 22008: 12009: 42010: 52011: 32012: 32013: 12014: 42015: 22017: 12019: 22020: 22021: 22022: 32023: 32024: 22026 (partial year): 2
2007high 5 (2010) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAH

237in 2023

2009: 111 days median2010: 216 days median2011: 281 days median2012: 212 days median2014: 250 days median2022: 204 days median2023: 237 days median
2007high 281 (2011) · low 111 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CAH

1in 2025

2010: 22013: 12014: 12017: 12022: 6, 6 Class I2025: 1, 1 Class I
2007high 6 (2022) · low 0 (2007)2026

Class I (7 since 2007) Class II/III not classified

Adverse event reports per year · CAH

77in 2025

2007: 322008: 272009: 182010: 402011: 92012: 162013: 472014: 982015: 512016: 342017: 292018: 332019: 302020: 332021: 562022: 672023: 402024: 512025: 77
2007high 98 (2014) · low 9 (2011)2025

MAUDE reports naming product code CAH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—032
20081—027
20094111018
20105216240
2011328109
20123212016
20131—147
20144250198
20152—051
20160—034
20171—129
20180—033
20192—030
20202—033
20212—056
202232046 (6)67
20233237040
20242—051
20250—1 (1)77
20262—0—
Cite this page

510(k) Report. “K791307: Unipor Breathing Circuit Filter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K791307

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026