510(k) · Cleared
Recalled · Class II · 2016Bard Ureteral Stent
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
C.R. Bard, Inc. · FAD Stent, Ureteral
Cleared on May 27, 1983 after a 185-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled once.
- Decided
- May 27, 1983
- Review
- 185 days
- Class
- Class II
- Product code
- FAD
- Recalls
- 1
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FAD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FAD device
- #1 K251890 Disposable Ureteral Stentsscore 12.4 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 13, 2016 | Class II | Z-0403-2017 | Labeling Change Control | Labeling: Statement was added to the Warnings/Precautions section requesting end users to consider the presence of a knot if significant resistance is encountered during attempts at removal. |
No ancestor or descendant has a Class I recall.
How does its category compare?
All FAD devicesFAD Stent, Ureteral: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FAD
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FAD
186in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FAD
4in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FAD
634in 2025
MAUDE reports naming product code FAD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 1 | 43 |
| 2008 | 1 | — | 22 | 76 |
| 2009 | 0 | — | 2 | 123 |
| 2010 | 1 | — | 1 | 78 |
| 2011 | 0 | — | 0 | 95 |
| 2012 | 0 | — | 0 | 131 |
| 2013 | 0 | — | 0 | 82 |
| 2014 | 1 | — | 0 | 78 |
| 2015 | 0 | — | 0 | 130 |
| 2016 | 4 | 143 | 4 | 182 |
| 2017 | 8 | 266 | 0 | 265 |
| 2018 | 9 | 258 | 0 | 277 |
| 2019 | 5 | 263 | 6 | 261 |
| 2020 | 1 | — | 2 | 352 |
| 2021 | 2 | — | 1 | 531 |
| 2022 | 5 | 143 | 9 | 559 |
| 2023 | 0 | — | 0 | 691 |
| 2024 | 1 | — | 0 | 603 |
| 2025 | 4 | 186 | 4 | 634 |
| 2026 | 1 | — | 0 | — |
https://510kreport.com/device/K823487 · printed Nov 4, 2026
Cite this page
510(k) Report. “K823487: Bard Ureteral Stent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K823487
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Page last updated Nov 3, 2026