510(k) Report

510(k) · Cleared

Cleared

Collins Eagle II

K831779510(k) TraditionalCleared Aug 26, 198385-day reviewClass II21 CFR 868.1880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Warren E. Collins, Inc. · BZC Calculator, Pulmonary Function Data

Cleared on Aug 26, 1983 after an 85-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 8 later devices descend from it.

Decided
Aug 26, 1983
Review
85 days
Class
Class II
Product code
BZC
Recalls
None
Predicates
0

8 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2005: 1 descendant cleared2010: 1 descendant cleared2015: 2 descendants cleared2020: 1 descendant cleared2016: 1 descendant cleared2022: 1 descendant cleared2026: 1 descendant cleared19801990200020102020
  1. This deviceK831779 Collins Eagle IIWarren E. Collins, Inc. · 1983
  2. Descendant · cites it directly · 7 of its ownK051572 Koko LegendPulmonary Data Services, Inc. · 2005
  3. Descendant · 2 generations on · 6 of its ownK100687 Vitalograph Hand Held Spirometer, Model 2120Vitalograph (Ireland), Ltd. · 2010
  4. Descendant · 3 generations on · 2 of its ownK200550 Vitalograph Model 2120 In2itive eDiaryVitalograph Ireland, Ltd. · 2020
  5. Descendant · 4 generations on · 1 of its ownK212938 Vitalograph Model 6000 AlphaVitalograph Ireland, Ltd. · 2022
  6. Descendant · 3 generations on · 1 of its ownK142812 Vitalograph Model 6800 PneumotracVitalograph (Ireland), Ltd. · 2015

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2005: 12010: 12015: 22016: 12020: 12022: 12026: 1
2005high 2 (2015) · low 0 (2006)2026

Most influential descendants

Showing 5 of 8 · See all
  • K051572Koko LegendPulmonary Data Services, Inc. · 2005 · cites it directly7descendants
  • K100687Vitalograph Hand Held Spirometer, Model 2120Vitalograph (Ireland), Ltd. · 2010 · 2 generations on6descendants
  • K200550Vitalograph Model 2120 In2itive eDiaryVitalograph Ireland, Ltd. · 2020 · 3 generations on2descendants
  • K212938Vitalograph Model 6000 AlphaVitalograph Ireland, Ltd. · 2022 · 4 generations on1descendant
  • K142812Vitalograph Model 6800 PneumotracVitalograph (Ireland), Ltd. · 2015 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K831779Collins Eagle IIWarren E. Collins, Inc.1983—
+1K051572Koko LegendPulmonary Data Services, Inc.2005—
+2K100687Vitalograph Hand Held Spirometer, Model 2120Vitalograph (Ireland), Ltd.2010—
+3K200550Vitalograph Model 2120 In2itive eDiaryVitalograph Ireland, Ltd.2020—
+4K212938Vitalograph Model 6000 AlphaVitalograph Ireland, Ltd.2022—
+3K142812Vitalograph Model 6800 PneumotracVitalograph (Ireland), Ltd.2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
201010
201520
201610
202010
202210
202610
FIG. 1 — Lineage of K831779, 1983–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZC device

  1. #1 K240293 STSscore 9.8 · 7 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (8)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K051572Koko LegendPulmonary Data Services, Inc.20057

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K051572 (Pulmonary Data Services, Inc., 2005) has gone furthest, with 7 descendants of its own.

How does its category compare?

All BZC devices

BZC Calculator, Pulmonary Function Data: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZC

1in 2024

2007: 12011: 12014: 22015: 12016: 12017: 12018: 12019: 22024: 1
2007high 2 (2014) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZC

Too few BZC 510(k)s in any year since 2007 to give a median.

Recalls per year · BZC

3in 2009

2009: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BZC

3in 2025

2007: 12008: 32016: 42017: 12018: 12019: 72020: 32021: 52022: 92023: 82024: 82025: 3
2007high 9 (2022) · low 0 (2009)2025

MAUDE reports naming product code BZC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
20080—03
20090—30
20100—00
20111—00
20120—00
20130—00
20142—00
20151—00
20161—04
20171—01
20181—01
20192—07
20200—03
20210—05
20220—09
20230—08
20241—08
20250—03
20260—0—
Cite this page

510(k) Report. “K831779: Collins Eagle II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K831779

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026