510(k) · Cleared
Recalled · 2008Vanadium Excavators Sizes 0-6
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Henry Schein, Inc. · EKC Excavator, Dental, Operative
Cleared on Feb 21, 1984 after a 90-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled 8 times.
- Decided
- Feb 21, 1984
- Review
- 90 days
- Class
- Class I
- Product code
- EKC
- Recalls
- 8
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EKC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Nov 14, 2008 | Not classified | Z-0152-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0153-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0154-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0157-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0151-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0156-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0158-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
| Nov 14, 2008 | Not classified | Z-0155-2010 | Component change control | The tips of the Neos Vanadium Excavators may prematurely release from the handle during use, and if so, the tip may be accidentally swallowed. |
The 5 latest of 8 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
How does its category compare?
All EKC devicesEKC Excavator, Dental, Operative: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · EKC
FDA has decided no EKC device since 2007.
Median 510(k) review, days · EKC
Too few EKC 510(k)s in any year since 2007 to give a median.
Recalls per year · EKC
8in 2008
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · EKC
1in 2025
MAUDE reports naming product code EKC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 8 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 2 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 2 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 1 |
| 2026 | 0 | — | 0 | — |
https://510kreport.com/device/K834055 · printed Nov 4, 2026
Cite this page
510(k) Report. “K834055: Vanadium Excavators Sizes 0-6.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K834055
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Page last updated Nov 3, 2026