510(k) Report

510(k) · Cleared

Cleared

Silicone Suction & Irrigation Drain

K840323510(k) TraditionalCleared Apr 25, 198491-day reviewClass I21 CFR 878.4200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Superior Plastic Products Corp. · GBX Catheter, Irrigation

Cleared on Apr 25, 1984 after a 91-day review. FDA has not posted a summary or statement for it, so its predicates are not known.

Decided
Apr 25, 1984
Review
91 days
Class
Class I
Product code
GBX
Recalls
None
Predicates
0

FDA has not posted a summary or statement for it, so its predicates are not known.

FIG. 1 — Lineage of K840323Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GBX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All GBX devices

GBX Catheter, Irrigation: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GBX

1in 2014

2008: 12014: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GBX

Too few GBX 510(k)s in any year since 2007 to give a median.

Recalls per year · GBX

6in 2025

2010: 12017: 12021: 12022: 292025: 6
2007high 29 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GBX

1,179in 2025

2007: 112008: 162009: 242010: 352011: 412012: 462013: 492014: 512015: 582016: 862017: 1762018: 2772019: 1962020: 1982021: 3832022: 4772023: 6282024: 9452025: 1,179
2007high 1,179 (2025) · low 11 (2007)2025

MAUDE reports naming product code GBX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—011
20081—016
20090—024
20100—135
20110—041
20120—046
20130—049
20141—051
20150—058
20160—086
20170—1176
20180—0277
20190—0196
20200—0198
20210—1383
20220—29477
20230—0628
20240—0945
20250—61,179
20260—0—
Cite this page

510(k) Report. “K840323: Silicone Suction & Irrigation Drain.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K840323

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Page last updated Nov 3, 2026