510(k) · Cleared
Recalled · Class II · 2017Panoramic X-Ray Model PC-1000
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Panoramic Corp. · EHD Unit, X-Ray, Extraoral With Timer
Cleared on Feb 13, 1987 after a 23-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled 3 times.
- Decided
- Feb 13, 1987
- Review
- 23 days
- Class
- Class II
- Product code
- EHD
- Recalls
- 3
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EHD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new EHD device
- #1 K260795 Hand-held Dental X-ray System (HyperLight-M)score 14.1 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jul 14, 2017 | Class II | Z-0517-2018 | Device Design | The lift motor used to raise and lower the overhead chassis will wear if not properly maintained according to the maintenance schedule. |
| Aug 19, 2016 | Class II | Z-0016-2017 | Device Design | Panoramic Corporation is performing a voluntary Medical Device Correction on certain PC-1000 X-ray systems due to the potential for a safety nut to be ineffective, which could result in blunt force trauma that may impact the head, neck or… |
| Jun 4, 2015 | Class II | Z-2538-2015 | Equipment maintenance | Jackscrew nut part failure potentially leading to device malfunction and patient/operator injury. |
No ancestor or descendant has a Class I recall.
How does its category compare?
All EHD devicesEHD Unit, X-Ray, Extraoral With Timer: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · EHD
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · EHD
58in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · EHD
1in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · EHD
6in 2024
MAUDE reports naming product code EHD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 5 |
| 2008 | 5 | 49 | 0 | 6 |
| 2009 | 4 | 92 | 0 | 38 |
| 2010 | 4 | 268 | 3 | 47 |
| 2011 | 3 | 102 | 3 | 26 |
| 2012 | 2 | — | 0 | 22 |
| 2013 | 4 | 216 | 0 | 21 |
| 2014 | 3 | 107 | 1 | 20 |
| 2015 | 1 | — | 0 | 110 |
| 2016 | 2 | — | 1 | 63 |
| 2017 | 4 | 28 | 1 | 66 |
| 2018 | 5 | 30 | 0 | 21 |
| 2019 | 4 | 173 | 0 | 21 |
| 2020 | 2 | — | 0 | 4 |
| 2021 | 1 | — | 0 | 4 |
| 2022 | 8 | 58 | 0 | 4 |
| 2023 | 8 | 147 | 0 | 2 |
| 2024 | 7 | 58 | 0 | 6 |
| 2025 | 1 | — | 0 | 0 |
| 2026 | 6 | 128 | 0 | — |
https://510kreport.com/device/K870236 · printed Nov 6, 2026
Cite this page
510(k) Report. “K870236: Panoramic X-Ray Model PC-1000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K870236
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Page last updated Nov 3, 2026