510(k) · Cleared
ClearedModified Biovac:Lfa Laser Fume Evacuation System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Stackhouse Assoc. · FYD Apparatus, Exhaust, Surgical
Cleared on Jan 27, 1988 after an 86-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 8 later devices descend from it.
- Decided
- Jan 27, 1988
- Review
- 86 days
- Class
- Class II
- Product code
- FYD
- Recalls
- None
- Predicates
- 0
8 later devices descend from it, 2 citing it directly.
- This deviceK874512 Modified Biovac:Lfa Laser Fume Evacuation SystemStackhouse Assoc. · 1988
- Descendant · cites it directly · 5 of its ownK990037 Neptune Waste Management SystemAmerican Immuno Tech · 1999 · Recalled
- Descendant · cites it directly · 5 of its ownK980915 Valleylab Optimumm Smoke Evacuator SystemValleylab, Inc. · 1998
- Descendant · 2 generations on · 4 of its ownK081047 Transposal Ultra SystemsDornoch Medical Systems, Inc. · 2008
- Descendant · 2 generations on · 3 of its ownK132671 Stryker Neptune 2 Waste Managment SystemStryker Corporation · 2013 · Recalled
- Descendant · 3 generations on · 1 of its ownK153407 Stryker Neptune 3 Waste Management SystemStryker Corporation · 2016 · Recalled
Showing 5 of 8 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 8 · See all- K990037Neptune Waste Management SystemAmerican Immuno Tech · 1999 · cites it directly5descendants
- K980915Valleylab Optimumm Smoke Evacuator SystemValleylab, Inc. · 1998 · cites it directly5descendants
- K081047Transposal Ultra SystemsDornoch Medical Systems, Inc. · 2008 · 2 generations on4descendants
- K132671Stryker Neptune 2 Waste Managment SystemStryker Corporation · 2013 · 2 generations on3descendants
- K153407Stryker Neptune 3 Waste Management SystemStryker Corporation · 2016 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K874512 | Modified Biovac:Lfa Laser Fume Evacuation System | Stackhouse Assoc. | 1988 | — |
| +1 | K990037 | Neptune Waste Management System | American Immuno Tech | 1999 | 2 |
| +1 | K980915 | Valleylab Optimumm Smoke Evacuator System | Valleylab, Inc. | 1998 | — |
| +2 | K081047 | Transposal Ultra Systems | Dornoch Medical Systems, Inc. | 2008 | — |
| +2 | K132671 | Stryker Neptune 2 Waste Managment System | Stryker Corporation | 2013 | 5 |
| +3 | K153407 | Stryker Neptune 3 Waste Management System | Stryker Corporation | 2016 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2008 | 1 | 0 |
| 2013 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FYD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FYD device
- #1 K240127 PlumeSafe X5 Smoke Management Systemscore 8.7 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (8)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K990037 (American Immuno Tech, 1999) has gone furthest, with 5 descendants of its own.
How does its category compare?
All FYD devicesFYD Apparatus, Exhaust, Surgical: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FYD
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · FYD
71in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FYD
3so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FYD
15in 2025
MAUDE reports naming product code FYD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 3 |
| 2008 | 0 | — | 0 | 4 |
| 2009 | 1 | — | 0 | 5 |
| 2010 | 0 | — | 1 | 39 |
| 2011 | 0 | — | 0 | 150 |
| 2012 | 0 | — | 0 | 120 |
| 2013 | 0 | — | 0 | 142 |
| 2014 | 1 | — | 0 | 71 |
| 2015 | 1 | — | 0 | 21 |
| 2016 | 0 | — | 0 | 2 |
| 2017 | 1 | — | 0 | 3 |
| 2018 | 1 | — | 0 | 5 |
| 2019 | 3 | 71 | 0 | 11 |
| 2020 | 1 | — | 0 | 11 |
| 2021 | 1 | — | 0 | 20 |
| 2022 | 1 | — | 0 | 46 |
| 2023 | 0 | — | 0 | 19 |
| 2024 | 2 | — | 0 | 11 |
| 2025 | 0 | — | 0 | 15 |
| 2026 | 0 | — | 3 | — |
https://510kreport.com/device/K874512 · printed Nov 6, 2026
Cite this page
510(k) Report. “K874512: Modified Biovac:Lfa Laser Fume Evacuation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K874512
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026