510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Centurion Circlamp

K890897510(k) TraditionalCleared Mar 28, 198934-day reviewClass II21 CFR 884.4530Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Tri-State Hospital Supply Corp. · HFX Clamp, Circumcision

Cleared on Mar 28, 1989 after a 34-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 3 later devices descend from it. It has been recalled 7 times.

Decided
Mar 28, 1989
Review
34 days
Class
Class II
Product code
HFX
Recalls
7
Predicates
0

3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared2005: 1 descendant cleared2026: 1 descendant cleared1990200020102020
  1. This deviceK890897 Centurion CirclampTri-State Hospital Supply Corp. · 1989
  2. Descendant · cites it directly · 1 of its ownK040052 Fine Surgical Circumcision ClampFine Surgical Instrument Corp. · 2004
  3. Descendant · 2 generations on · 0 of its ownK251687 Konig Bell Circumcision ClampMedline Industries, LP · 2026
  4. Descendant · cites it directly · 0 of its ownK043533 Surgical Design Circumcision ClampSurgical Design, Inc. · 2005 · Recalled

Most influential descendants

Showing 3 of 3 · See all
  • K040052Fine Surgical Circumcision ClampFine Surgical Instrument Corp. · 2004 · cites it directly1descendant
  • K251687Konig Bell Circumcision ClampMedline Industries, LP · 2026 · 2 generations on0descendants
  • K043533Surgical Design Circumcision ClampSurgical Design, Inc. · 2005 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K890897Centurion CirclampTri-State Hospital Supply Corp.1989—
+1K040052Fine Surgical Circumcision ClampFine Surgical Instrument Corp.2004—
+2K251687Konig Bell Circumcision ClampMedline Industries, LP2026—
+1K043533Surgical Design Circumcision ClampSurgical Design, Inc.20051

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200510
202610
FIG. 1 — Lineage of K890897, 1989–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HFX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HFX device

  1. #1 K251687 Konig Bell Circumcision Clampscore 11.2 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K040052Fine Surgical Circumcision ClampFine Surgical Instrument Corp.20041
K043533Surgical Design Circumcision ClampSurgical Design, Inc.20050

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 3, 2024Class IIZ-0133-2025Device DesignProduct has been identified as having holes in the packaging.
May 23, 2023Class IIZ-2649-2023Process controlThe kits incorrectly contain CirClamp subassembly 345CRSAK which results in the kits containing an incorrect bell and base size.
Mar 2, 2023Class IIZ-1407-2023Under Investigation by firmThe CirClamp subassembly found in the kit was the incorrect size.
Aug 28, 2019Class IIZ-0120-2020Process controlA mismatch between the angle of the hole in the base and the angle of the bell, which may cause the clamp to remove foreskin without the use of a scalpel.
Aug 28, 2019Class IIZ-0121-2020Process controlA mismatch between the angle of the hole in the base and the angle of the bell, which may cause the clamp to remove foreskin without the use of a scalpel.
Apr 12, 2005Not classifiedZ-0837-05OtherNot labeled as reprocessed, when this lot has been reprocessed.
Apr 12, 2005Not classifiedZ-0836-05OtherLot 11224 may contain a 1.1 cm clamp and bell and neither lot is labeled as reprocessed, when they have been reprocessed.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K040052 (Fine Surgical Instrument Corp., 2004) has gone furthest, with 1 descendant of its own.

How does its category compare?

All HFX devices

HFX Clamp, Circumcision: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HFX

1in 2023

2007: 22010: 12012: 22013: 12015: 22022: 12023: 12026 (partial year): 1
2007high 2 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HFX

Too few HFX 510(k)s in any year since 2007 to give a median.

Recalls per year · HFX

1in 2024

2011: 32014: 22016: 12019: 22024: 1
2007high 3 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HFX

122in 2025

2007: 172008: 62009: 202010: 212011: 122012: 142013: 162014: 202015: 212016: 1472017: 252018: 132019: 112020: 222021: 52022: 32023: 332024: 1212025: 122
2007high 147 (2016) · low 3 (2022)2025

MAUDE reports naming product code HFX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—017
20080—06
20090—020
20101—021
20110—312
20122—014
20131—016
20140—220
20152—021
20160—1147
20170—025
20180—013
20190—211
20200—022
20210—05
20221—03
20231—033
20240—1121
20250—0122
20261—0—
Cite this page

510(k) Report. “K890897: Centurion Circlamp.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K890897

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026