510(k) · Cleared
Recalled · Class II · 2019Urethral Balloon Dilation Catheter Set
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cook Urological, Inc. · KOE Dilator, Urethral
Cleared on Nov 17, 1989 after a 213-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled once.
- Decided
- Nov 17, 1989
- Review
- 213 days
- Class
- Class II
- Product code
- KOE
- Recalls
- 1
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KOE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KOE device
- #1 K191061 Optilume Basic Urological Balloon Dilation…score -0.8 · 3 generations · no Class I recall
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jan 4, 2019 | Class II | Z-0970-2020 | Process control | The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. |
No ancestor or descendant has a Class I recall.
How does its category compare?
All KOE devicesKOE Dilator, Urethral: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KOE
1in 2020
2026 to Oct 25, outlined.
Median 510(k) review, days · KOE
Too few KOE 510(k)s in any year since 2007 to give a median.
Recalls per year · KOE
2in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KOE
11in 2025
MAUDE reports naming product code KOE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 1 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 3 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 4 |
| 2013 | 0 | — | 0 | 4 |
| 2014 | 0 | — | 0 | 4 |
| 2015 | 0 | — | 0 | 9 |
| 2016 | 0 | — | 0 | 3 |
| 2017 | 0 | — | 0 | 12 |
| 2018 | 0 | — | 0 | 23 |
| 2019 | 0 | — | 2 | 20 |
| 2020 | 1 | — | 0 | 23 |
| 2021 | 0 | — | 0 | 19 |
| 2022 | 0 | — | 0 | 15 |
| 2023 | 0 | — | 0 | 20 |
| 2024 | 0 | — | 0 | 22 |
| 2025 | 0 | — | 0 | 11 |
| 2026 | 0 | — | 0 | — |