510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Collagen Implants for the Lacrimal Efficiency Test

K895342510(k) TraditionalCleared Nov 2, 198963-day reviewClass URecalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Lacrimedics, Inc. · LZU Plug, Punctum

Cleared on Nov 2, 1989 after a 63-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 3 later devices descend from it. It has been recalled once.

Decided
Nov 2, 1989
Review
63 days
Class
Class U
Product code
LZU
Recalls
1
Predicates
0

3 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared2006: 1 descendant cleared2002: 1 descendant cleared1990200020102020
  1. This deviceK895342 Collagen Implants for the Lacrimal Efficiency TestLacrimedics, Inc. · 1989
  2. Descendant · cites it directly · 1 of its ownK013613 Soft Plug Absorbable Plug-SAOasis Medical, Inc. · 2002 · Recalled
  3. Descendant · cites it directly · 0 of its ownK140026 Collasyn Plug for the Lacrimal Efficiency TestLacrimedics, Inc. · 2014 · Recalled
  4. Descendant · cites it directly · 0 of its ownK053333 Eaglevision Gellanserts, Model Ref 0040Eagle Vision, Inc. · 2006

Most influential descendants

Showing 3 of 3 · See all
  • K013613Soft Plug Absorbable Plug-SAOasis Medical, Inc. · 2002 · cites it directly1descendant
  • K140026Collasyn Plug for the Lacrimal Efficiency TestLacrimedics, Inc. · 2014 · cites it directly0descendants
  • K053333Eaglevision Gellanserts, Model Ref 0040Eagle Vision, Inc. · 2006 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K895342Collagen Implants for the Lacrimal Efficiency TestLacrimedics, Inc.1989—
+1K013613Soft Plug Absorbable Plug-SAOasis Medical, Inc.20021
+1K140026Collasyn Plug for the Lacrimal Efficiency TestLacrimedics, Inc.20141
+1K053333Eaglevision Gellanserts, Model Ref 0040Eagle Vision, Inc.2006—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200610
201410
FIG. 1 — Lineage of K895342, 1989–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZU? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZU device

  1. #1 K241229 Hello,eyes® BIO Plugscore 8.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (3)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K013613Soft Plug Absorbable Plug-SAOasis Medical, Inc.20021
K140026Collasyn Plug for the Lacrimal Efficiency TestLacrimedics, Inc.20140
K053333Eaglevision Gellanserts, Model Ref 0040Eagle Vision, Inc.20060

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 17, 2022Class IIZ-0709-2022Packaging process controlThe sterile pouch seal may contain channels that could affect the seal integrity and potentially compromise sterility.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K013613 (Oasis Medical, Inc., 2002) has gone furthest, with 1 descendant of its own.

How does its category compare?

All LZU devices

LZU Plug, Punctum: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LZU

1in 2024

2009: 12014: 32015: 12016: 12017: 12019: 12022: 22024: 1
2007high 3 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZU

148in 2014

2014: 148 days median
2007high 148 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZU

2in 2022

2022: 2
2007high 2 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZU

3in 2025

2007: 102008: 122009: 112010: 52011: 62012: 72013: 172014: 102015: 12017: 32018: 22020: 22023: 52024: 12025: 3
2007high 17 (2013) · low 0 (2016)2025

MAUDE reports naming product code LZU, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—010
20080—012
20091—011
20100—05
20110—06
20120—07
20130—017
20143148010
20151—01
20161—00
20171—03
20180—02
20191—00
20200—02
20210—00
20222—20
20230—05
20241—01
20250—03
20260—0—
Cite this page

510(k) Report. “K895342: Collagen Implants for the Lacrimal Efficiency Test.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K895342

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026