510(k) Report

510(k) · Cleared

Cleared

Modified Assess (R) Peak Flow Meter

K902292510(k) TraditionalCleared Aug 10, 199080-day reviewClass II21 CFR 868.1860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Health Products, Inc. · BZH Meter, Peak Flow, Spirometry

Cleared on Aug 10, 1990 after an 80-day review. FDA has not posted a summary or statement for it, so its predicates are not known.

Decided
Aug 10, 1990
Review
80 days
Class
Class II
Product code
BZH
Recalls
None
Predicates
0

FDA has not posted a summary or statement for it, so its predicates are not known.

FIG. 1 — Lineage of K902292Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZH device

  1. #1 K252802 Peak Flow Meter (PF-10(BR-PEF231))score 13.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All BZH devices

BZH Meter, Peak Flow, Spirometry: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZH

3in 2024

2009: 22010: 22013: 12014: 12016: 12017: 12018: 32019: 12020: 22021: 12023: 12024: 32026 (partial year): 2
2007high 3 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZH

371in 2024

2018: 115 days median2024: 371 days median
2007high 371 (2024) · low 115 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZH

No recall names BZH since 2007.

Adverse event reports per year · BZH

1in 2015

2007: 12011: 12013: 32014: 222015: 1
2007high 22 (2014) · low 0 (2008)2025

MAUDE reports naming product code BZH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—00
20092—00
20102—00
20110—01
20120—00
20131—03
20141—022
20150—01
20161—00
20171—00
2018311500
20191—00
20202—00
20211—00
20220—00
20231—00
2024337100
20250—00
20262—0—
Cite this page

510(k) Report. “K902292: Modified Assess (R) Peak Flow Meter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K902292

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Page last updated Nov 3, 2026