510(k) · Cleared
ClearedDacron R Surgical Sutures
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Sharppoint, Inc. · GAS Suture, Nonabsorbable, Synthetic, Polyester
Cleared on Oct 16, 1990 after a 29-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 12 later devices descend from it.
- Decided
- Oct 16, 1990
- Review
- 29 days
- Class
- Class II
- Product code
- GAS
- Recalls
- None
- Predicates
- 0
12 later devices descend from it, 1 citing it directly.
- This deviceK904263 Dacron R Surgical SuturesSharppoint, Inc. · 1990
- Descendant · cites it directly · 11 of its ownK060165 Axyaflex Polyester SutureAxya Medical, Inc. · 2006
- Descendant · 2 generations on · 9 of its ownK080684 WG-Surgical Sutures with NeedleFoosin Medical Supplies, Inc. · 2008
- Descendant · 3 generations on · 4 of its ownK161633 Rexlon, RexsilSm Eng Co., Ltd. · 2017
- Descendant · 3 generations on · 1 of its ownK173747 RexleneSm Eng Co., Ltd. · 2018
- Descendant · 4 generations on · 1 of its ownK180701 SafePath Suturing SystemSafepath Medical, Inc. · 2018
Showing 5 of 12 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 12 · See all- K060165Axyaflex Polyester SutureAxya Medical, Inc. · 2006 · cites it directly11descendants
- K080684WG-Surgical Sutures with NeedleFoosin Medical Supplies, Inc. · 2008 · 2 generations on9descendants
- K161633Rexlon, RexsilSm Eng Co., Ltd. · 2017 · 3 generations on4descendants
- K173747RexleneSm Eng Co., Ltd. · 2018 · 3 generations on1descendant
- K180701SafePath Suturing SystemSafepath Medical, Inc. · 2018 · 4 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K904263 | Dacron R Surgical Sutures | Sharppoint, Inc. | 1990 | — |
| +1 | K060165 | Axyaflex Polyester Suture | Axya Medical, Inc. | 2006 | — |
| +2 | K080684 | WG-Surgical Sutures with Needle | Foosin Medical Supplies, Inc. | 2008 | — |
| +3 | K161633 | Rexlon, Rexsil | Sm Eng Co., Ltd. | 2017 | — |
| +3 | K173747 | Rexlene | Sm Eng Co., Ltd. | 2018 | — |
| +4 | K180701 | SafePath Suturing System | Safepath Medical, Inc. | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 2 | 0 |
| 2008 | 1 | 0 |
| 2015 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GAS device
- #1 K203081 RAM COR-SUTURE QUCIK LOAD Surgical Suture…score 1.9 · 6 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (12)
See all 121 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K060165 | Axyaflex Polyester Suture | 2006 | 11 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K060165 (Axya Medical, Inc., 2006) has gone furthest, with 11 descendants of its own.
How does its category compare?
All GAS devicesGAS Suture, Nonabsorbable, Synthetic, Polyester: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GAS
2in 2020
2026 to Oct 25, outlined.
Median 510(k) review, days · GAS
Too few GAS 510(k)s in any year since 2007 to give a median.
Recalls per year · GAS
No recall names GAS since 2007.
Adverse event reports per year · GAS
3in 2025
MAUDE reports naming product code GAS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 35 |
| 2008 | 0 | — | 0 | 47 |
| 2009 | 0 | — | 0 | 56 |
| 2010 | 1 | — | 0 | 24 |
| 2011 | 0 | — | 0 | 25 |
| 2012 | 0 | — | 0 | 73 |
| 2013 | 0 | — | 0 | 21 |
| 2014 | 0 | — | 0 | 12 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 2 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 3 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 2 | — | 0 | 1 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 3 |
| 2026 | 0 | — | 0 | — |
https://510kreport.com/device/K904263 · printed Nov 4, 2026
Cite this page
510(k) Report. “K904263: Dacron R Surgical Sutures.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K904263
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026