510(k) Report

510(k) · Cleared

Cleared

Townley Total Knee (TTK)

K904448510(k) TraditionalCleared Jul 17, 1991292-day reviewClass II21 CFR 888.3560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biopro, Inc. · JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Cleared on Jul 17, 1991 after a 292-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 20 later devices descend from it.

Decided
Jul 17, 1991
Review
292 days
Class
Class II
Product code
JWH
Recalls
None
Predicates
0

20 later devices descend from it, 6 citing it directly.

Descendants, by year cleared 2014: 3 descendants cleared2013: 2 descendants cleared2015: 3 descendants cleared2016: 1 descendant cleared2019: 3 descendants cleared2017: 1 descendant cleared2023: 1 descendant cleared2020: 1 descendant cleared2024: 3 descendants cleared2022: 1 descendant cleared2026: 1 descendant cleared1990200020102020
  1. This deviceK904448 Townley Total Knee (TTK)Biopro, Inc. · 1991
  2. Descendant · cites it directly · 12 of its ownK141471 Journey II XR Knee SystemSmith & Nephew, Inc. · 2014
  3. Descendant · 2 generations on · 8 of its ownK152315 JOURNEY II Uni Tibial Base and InsertSmith & Nephew, Inc. · 2015
  4. Descendant · 3 generations on · 7 of its ownK190085 Journey II Unicompartmental Knee SystemSmith & Nephew, Inc. · 2019 · Recalled
  5. Descendant · cites it directly · 6 of its ownK122160 Vanguard XP Knee SystemBiomet Manufacturing Corp · 2013 · Recalled
  6. Descendant · 2 generations on · 4 of its ownK152726 JOURNEY II XR Knee SystemSmith & Nephew, Inc. · 2015

Showing 5 of 20 descendants. See all descendants

Descendants cleared per year

2013: 22014: 32015: 32016: 12017: 12019: 32020: 12022: 12023: 12024: 32026: 1
2013high 3 (2014) · low 0 (2018)2026

Most influential descendants

Showing 5 of 20 · See all
  • K141471Journey II XR Knee SystemSmith & Nephew, Inc. · 2014 · cites it directly12descendants
  • K152315JOURNEY II Uni Tibial Base and InsertSmith & Nephew, Inc. · 2015 · 2 generations on8descendants
  • K190085Journey II Unicompartmental Knee SystemSmith & Nephew, Inc. · 2019 · 3 generations on7descendants
  • K122160Vanguard XP Knee SystemBiomet Manufacturing Corp · 2013 · cites it directly6descendants
  • K152726JOURNEY II XR Knee SystemSmith & Nephew, Inc. · 2015 · 2 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K904448Townley Total Knee (TTK)Biopro, Inc.1991—
+1K141471Journey II XR Knee SystemSmith & Nephew, Inc.2014—
+2K152315JOURNEY II Uni Tibial Base and InsertSmith & Nephew, Inc.2015—
+3K190085Journey II Unicompartmental Knee SystemSmith & Nephew, Inc.20193
+1K122160Vanguard XP Knee SystemBiomet Manufacturing Corp201312
+2K152726JOURNEY II XR Knee SystemSmith & Nephew, Inc.2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201320
201430
201530
201610
201710
201930
202010
202210
202310
202430
202610
FIG. 1 — Lineage of K904448, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JWH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JWH device

  1. #1 K221479 Persona Personalized Knee Systemscore 22.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (20)

See all 20

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K141471Journey II XR Knee SystemSmith & Nephew, Inc.201412
K122160Vanguard XP Knee SystemBiomet Manufacturing Corp20136
K132873Vanguard XP Knee SystemBiomet, Inc.20133
K141407Vanguard XP Femoral Component (Gen II)/Vanguard XP Femoral TrialBiomet, Inc.20142
K153657Vanguard XP Knee SystemBiomet, Inc.20161
K143635KINETIS Total Knee SystemMako Surgical20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K141471 (Smith & Nephew, Inc., 2014) has gone furthest, with 12 descendants of its own.

How does its category compare?

All JWH devices

JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JWH

20in 2025

2007: 182008: 172009: 112010: 192011: 252012: 332013: 312014: 332015: 272016: 182017: 252018: 252019: 282020: 222021: 242022: 172023: 202024: 192025: 202026 (partial year): 12
2007high 33 (2012) · low 11 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JWH

55in 2025

2007: 74 days median2008: 81 days median2009: 168 days median2010: 85 days median2011: 87 days median2012: 85 days median2013: 128 days median2014: 98 days median2015: 87 days median2016: 88 days median2017: 118 days median2018: 90 days median2019: 133 days median2020: 59 days median2021: 61 days median2022: 56 days median2023: 57 days median2024: 89 days median2025: 55 days median2026 (partial year): 63 days median
2007high 168 (2009) · low 55 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JWH

2in 2025

2007: 142008: 102009: 1092010: 322011: 272012: 852013: 312014: 132015: 112016: 172017: 612018: 142019: 52020: 22021: 82022: 122023: 672024: 72025: 22026 (partial year): 4
2007high 109 (2009) · low 2 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JWH

9,306in 2025

2007: 1,3052008: 1,4832009: 1,8702010: 3,2862011: 5,1332012: 5,2032013: 6,1352014: 6,7222015: 6,8812016: 7,5862017: 12,2632018: 14,0712019: 14,9872020: 12,5922021: 9,4082022: 8,3642023: 8,9472024: 10,8282025: 9,306
2007high 14,987 (2019) · low 1,305 (2007)2025

MAUDE reports naming product code JWH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071874141,305
20081781101,483
2009111681091,870
20101985323,286
20112587275,133
20123385855,203
201331128316,135
20143398136,722
20152787116,881
20161888177,586
2017251186112,263
201825901414,071
201928133514,987
20202259212,592
2021246189,408
20221756128,364
20232057678,947
20241989710,828
2025205529,306
202612634—
Cite this page

510(k) Report. “K904448: Townley Total Knee (TTK).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K904448

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026