510(k) Report

510(k) · Decided

Recalled · Class II · 2016

Customed Cardiovascular Pack

K904693510(k) TraditionalDecided Jan 2, 199178-day reviewClass II21 CFR 878.4370Recalls 6

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Customed, Inc. · KKX Drape, Surgical, Antimicrobial

Cleared on Jan 2, 1991 after a 78-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled 6 times.

Decided
Jan 2, 1991
Review
78 days
Class
Class II
Product code
KKX
Recalls
6
Predicates
0

FDA has not posted a summary or statement for it, so its predicates are not known.

FIG. 1 — Lineage of K904693Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KKX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KKX device

  1. #1 K222578 3M™ Ioban™ CHG Chlorhexidine Gluconate Incise…score 5.7 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 7, 2016Class IIZ-1455-2016PackagingRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.
Jul 10, 2015Class IIZ-2580-2015PackagingRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.
Jul 10, 2015Class IIZ-2602-2015PackagingRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.
Jul 10, 2015Class IIZ-2649-2015PackagingRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.
Jul 10, 2015Class IIZ-2581-2015PackagingRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.
Jul 10, 2015Class IIZ-2582-2015PackagingRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.

No ancestor or descendant has a Class I recall.

How does its category compare?

All KKX devices

KKX Drape, Surgical, Antimicrobial: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KKX

2in 2023

2007: 42008: 52009: 52010: 82011: 42012: 22013: 32014: 62015: 22017: 12020: 12021: 12023: 2
2007high 8 (2010) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KKX

182in 2014

2007: 181 days median2008: 164 days median2009: 114 days median2010: 107 days median2011: 147 days median2013: 227 days median2014: 182 days median
2007high 227 (2013) · low 107 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KKX

2in 2024

2007: 12010: 12011: 12012: 12013: 72014: 7, 7 Class I2016: 42024: 22026 (partial year): 2
2007high 7 (2013) · low 0 (2008)2026

Class I (7 since 2007) Class II/III not classified

Adverse event reports per year · KKX

24in 2025

2007: 242008: 242009: 272010: 252011: 572012: 402013: 632014: 282015: 332016: 562017: 302018: 322019: 412020: 162021: 412022: 192023: 322024: 192025: 24
2007high 63 (2013) · low 16 (2020)2025

MAUDE reports naming product code KKX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074181124
20085164024
20095114027
20108107125
20114147157
20122—140
20133227763
201461827 (7)28
20152—033
20160—456
20171—030
20180—032
20190—041
20201—016
20211—041
20220—019
20232—032
20240—219
20250—024
20260—2—
Cite this page

510(k) Report. “K904693: Customed Cardiovascular Pack.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K904693

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Page last updated Nov 3, 2026