510(k) Report

510(k) · Cleared

Cleared

Stryker Laparoscope

K910132510(k) TraditionalCleared Feb 21, 199143-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stryker Corp. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Feb 21, 1991 after a 43-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 107 later devices descend from it.

Decided
Feb 21, 1991
Review
43 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
0

107 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2014: 2 descendants cleared2009: 1 descendant cleared2025: 15 descendants cleared2016: 3 descendants cleared2015: 2 descendants cleared2011: 1 descendant cleared2021: 9 descendants cleared2018: 4 descendants cleared2019: 3 descendants cleared2013: 1 descendant cleared2017: 3 descendants cleared2022: 11 descendants cleared2020: 7 descendants cleared2023: 14 descendants cleared2026: 18 descendants cleared2024: 13 descendants cleared1990200020102020
  1. This deviceK910132 Stryker LaparoscopeStryker Corp. · 1991
  2. Descendant · cites it directly · 106 of its ownK091515 Spy Scope Intra-Operative Operating SystemNovadaq Technologies, Inc. · 2009 · Recalled
  3. Descendant · 2 generations on · 104 of its ownK101077 DA Vinci Fluorescence Imaging Vision System, Model FF 100Intuitive Surgical, Inc. · 2011 · Recalled
  4. Descendant · 3 generations on · 103 of its ownK124031 DA Vinci Fluorescence Imaging Vision SystemIntuitive Surgical, Inc. · 2013
  5. Descendant · 3 generations on · 87 of its ownK141077 DA Vinci Firefly Imaging SystemIntuitive Surgical, Inc. · 2014 · Recalled
  6. Descendant · cites it directly · 76 of its ownK142310 Stryker Infrared Fluorescence (IRF) Imaging SystemStryker Endoscopy · 2014

Showing 5 of 107 descendants. See all descendants

Descendants cleared per year

2009: 12011: 12013: 12014: 22015: 22016: 32017: 32018: 42019: 32020: 72021: 92022: 112023: 142024: 132025: 152026: 18
2009high 18 (2026) · low 0 (2010)2026

Most influential descendants

Showing 5 of 107 · See all
  • K091515Spy Scope Intra-Operative Operating SystemNovadaq Technologies, Inc. · 2009 · cites it directly106descendants
  • K101077DA Vinci Fluorescence Imaging Vision System, Model FF 100Intuitive Surgical, Inc. · 2011 · 2 generations on104descendants
  • K124031DA Vinci Fluorescence Imaging Vision SystemIntuitive Surgical, Inc. · 2013 · 3 generations on103descendants
  • K141077DA Vinci Firefly Imaging SystemIntuitive Surgical, Inc. · 2014 · 3 generations on87descendants
  • K142310Stryker Infrared Fluorescence (IRF) Imaging SystemStryker Endoscopy · 2014 · cites it directly76descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K910132Stryker LaparoscopeStryker Corp.1991—
+1K091515Spy Scope Intra-Operative Operating SystemNovadaq Technologies, Inc.20091
+2K101077DA Vinci Fluorescence Imaging Vision System, Model FF 100Intuitive Surgical, Inc.20112
+3K124031DA Vinci Fluorescence Imaging Vision SystemIntuitive Surgical, Inc.2013—
+3K141077DA Vinci Firefly Imaging SystemIntuitive Surgical, Inc.20142
+1K142310Stryker Infrared Fluorescence (IRF) Imaging SystemStryker Endoscopy2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201110
201310
201420
201520
201630
201730
201840
201930
202070
202190
2022110
2023140
2024130
2025150
2026180
FIG. 1 — Lineage of K910132, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (107)

See all 107

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091515Spy Scope Intra-Operative Operating SystemNovadaq Technologies, Inc.2009106
K142310Stryker Infrared Fluorescence (IRF) Imaging SystemStryker Endoscopy201476
K252010SPY LaparoscopeStryker Endoscopy20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K091515 (Novadaq Technologies, Inc., 2009) has gone furthest, with 106 descendants of its own.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—
Cite this page

510(k) Report. “K910132: Stryker Laparoscope.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K910132

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026