510(k) · Cleared
ClearedD-Dimer Wellcotest (HA10)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wellcome Diagnostics · DAP Fibrinogen And Fibrin Split Products, Antigen, Antiserum, Control
Cleared on Jan 31, 1992 after a 74-day review. FDA has not posted a summary or statement for it, so its predicates are not known.
- Decided
- Jan 31, 1992
- Review
- 74 days
- Class
- Class II
- Product code
- DAP
- Recalls
- None
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DAP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DAP device
- #1 K253985 INNOVANCE® D-Dimer 2.0 (SMN 10873803)score 13.0 · 5 generations · no Class I recall
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All DAP devicesDAP Fibrinogen And Fibrin Split Products, Antigen, Antiserum, Control: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DAP
1in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · DAP
127in 2008
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DAP
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DAP
2in 2025
MAUDE reports naming product code DAP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 4 |
| 2008 | 3 | 127 | 0 | 10 |
| 2009 | 1 | — | 0 | 13 |
| 2010 | 2 | — | 0 | 9 |
| 2011 | 1 | — | 0 | 14 |
| 2012 | 1 | — | 0 | 10 |
| 2013 | 0 | — | 0 | 8 |
| 2014 | 1 | — | 0 | 9 |
| 2015 | 1 | — | 1 | 38 |
| 2016 | 2 | — | 0 | 20 |
| 2017 | 1 | — | 0 | 17 |
| 2018 | 0 | — | 0 | 5 |
| 2019 | 0 | — | 0 | 9 |
| 2020 | 0 | — | 0 | 11 |
| 2021 | 0 | — | 1 | 7 |
| 2022 | 0 | — | 0 | 30 |
| 2023 | 0 | — | 0 | 4 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 2 | 2 |
| 2026 | 1 | — | 0 | — |
https://510kreport.com/device/K915203 · printed Nov 4, 2026
Cite this page
510(k) Report. “K915203: D-Dimer Wellcotest (HA10).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K915203
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Page last updated Nov 3, 2026