Bd Becton Dickinson Vacutainer Systems Preanalytic · MDB System, Blood Culturing
Cleared on Apr 22, 1992 after a 120-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 2 later devices descend from it. It has been recalled 6 times.
- Decided
- Apr 22, 1992
- Review
- 120 days
- Class
- Class I
- Product code
- MDB
- Recalls
- 6
- Predicates
- 0
2 later devices descend from it, 2 citing it directly.
- This deviceK915796 Bactec 9240 SystemBd Becton Dickinson Vacutainer Systems Preanalytic · 1992
- Descendant · cites it directly · 0 of its ownK172412 BacterioScan 216Dx SystemBacterioscan, Inc. · 2018
- Descendant · cites it directly · 0 of its ownK161306 BD BACTEC Standard Anaerobic/F Culture Vials Soybean-Casein Digest…Becton Dickinson · 2016
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K915796 | Bactec 9240 System | Bd Becton Dickinson Vacutainer Systems Preanalytic | 1992 | — |
| +1 | K172412 | BacterioScan 216Dx System | Bacterioscan, Inc. | 2018 | — |
| +1 | K161306 | BD BACTEC Standard Anaerobic/F Culture Vials Soybean-Casein Digest Broth in a… | Becton Dickinson | 2016 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2016 | 1 | 0 |
| 2018 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MDB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MDB device
- #1 K260213 BD BACTEC FXI Culture Systemscore 11.4 · 1 generation · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 23, 2025 | Class II | Z-0236-2026 | Software design | Product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of unauthorized access that may… |
| Oct 31, 2024 | Class II | Z-0594-2025 | Software design | BD confirmed that product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of… |
| Oct 31, 2024 | Class II | Z-0593-2025 | Software design | BD confirmed that product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of… |
| Oct 31, 2024 | Class II | Z-0596-2025 | Software design | BD confirmed that product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of… |
| Dec 9, 2013 | Class II | Z-0869-2014 | Nonconforming Material/Component | Improperly functioning component of a diagnostic medical device may cause false negative results in clinical specimens. |
| Dec 9, 2013 | Class II | Z-0870-2014 | Nonconforming Material/Component | Improperly functioning component of a diagnostic medical device may cause false negative results in clinical specimens. |
The 5 latest of 6 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K172412 (Bacterioscan, Inc., 2018) has gone furthest, with 0 descendants of its own.
How does its category compare?
All MDB devicesMDB System, Blood Culturing: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MDB
2in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · MDB
252in 2013
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MDB
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MDB
1,977in 2025
MAUDE reports naming product code MDB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 2 | 1 |
| 2008 | 1 | — | 0 | 3 |
| 2009 | 0 | — | 4 | 1 |
| 2010 | 0 | — | 2 | 1 |
| 2011 | 0 | — | 2 | 6 |
| 2012 | 2 | — | 33 | 4 |
| 2013 | 4 | 252 | 3 | 5 |
| 2014 | 1 | — | 0 | 1 |
| 2015 | 0 | — | 2 | 12 |
| 2016 | 2 | — | 0 | 291 |
| 2017 | 2 | — | 0 | 121 |
| 2018 | 1 | — | 3 | 76 |
| 2019 | 2 | — | 0 | 147 |
| 2020 | 0 | — | 0 | 37 |
| 2021 | 0 | — | 0 | 1,184 |
| 2022 | 0 | — | 0 | 643 |
| 2023 | 2 | — | 1 | 1,232 |
| 2024 | 0 | — | 4 | 401 |
| 2025 | 0 | — | 2 | 1,977 |
| 2026 | 1 | — | 0 | — |
https://510kreport.com/device/K915796 · printed Nov 6, 2026
Cite this page
510(k) Report. “K915796: Bactec 9240 System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K915796
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026