510(k) · Cleared
ClearedPikos 01-a and Pikos E01-a Implantable Pacemaker
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biotronik, GmbH & Co. · DXY Implantable Pacemaker Pulse-Generator
Cleared on Aug 19, 1993 after a 422-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 1 later device descends from it.
- Decided
- Aug 19, 1993
- Review
- 422 days
- Class
- Class III
- Product code
- DXY
- Recalls
- None
- Predicates
- 0
1 later device descends from it, 1 citing it directly.
- This deviceK923026 Pikos 01-a and Pikos E01-a Implantable PacemakerBiotronik, GmbH & Co. · 1993
- Descendant · cites it directly · 0 of its ownK993434 Pikos 01, Pikos E01, Pikos 01-B, Pikos E01-B, Pikos 01-a, Pikos E01-aBiotronik, Inc. · 1999
Most influential descendants
Showing 1 of 1 · See all- K993434Pikos 01, Pikos E01, Pikos 01-B, Pikos E01-B, Pikos 01-a, Pikos E01-aBiotronik, Inc. · 1999 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K923026 | Pikos 01-a and Pikos E01-a Implantable Pacemaker | Biotronik, GmbH & Co. | 1993 | — |
| +1 | K993434 | Pikos 01, Pikos E01, Pikos 01-B, Pikos E01-B, Pikos 01-a, Pikos E01-a | Biotronik, Inc. | 1999 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DXY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K993434 | Pikos 01, Pikos E01, Pikos 01-B, Pikos E01-B, Pikos 01-a, Pikos E01-a | 1999 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K993434 (Biotronik, Inc., 1999) has gone furthest, with 0 descendants of its own.
How does its category compare?
All DXY devicesDXY Implantable Pacemaker Pulse-Generator: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DXY
19in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DXY
Too few DXY 510(k)s in any year since 2007 to give a median.
Recalls per year · DXY
4in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DXY
810in 2025
MAUDE reports naming product code DXY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 2,407 |
| 2008 | 0 | — | 0 | 2,649 |
| 2009 | 0 | — | 6 | 3,750 |
| 2010 | 0 | — | 1 | 4,187 |
| 2011 | 0 | — | 2 | 6,050 |
| 2012 | 0 | — | 0 | 3,709 |
| 2013 | 0 | — | 0 | 2,682 |
| 2014 | 0 | — | 0 | 5,604 |
| 2015 | 0 | — | 0 | 1,022 |
| 2016 | 15 | — | 0 | 542 |
| 2017 | 51 | — | 4 | 1,047 |
| 2018 | 45 | — | 0 | 2,070 |
| 2019 | 19 | — | 0 | 1,799 |
| 2020 | 23 | — | 0 | 546 |
| 2021 | 20 | — | 0 | 560 |
| 2022 | 14 | — | 0 | 784 |
| 2023 | 19 | — | 0 | 922 |
| 2024 | 20 | — | 0 | 773 |
| 2025 | 19 | — | 0 | 810 |
| 2026 | 19 | — | 0 | — |
https://510kreport.com/device/K923026 · printed Nov 6, 2026
Cite this page
510(k) Report. “K923026: Pikos 01-a and Pikos E01-a Implantable Pacemaker.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K923026
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026