510(k) Report

510(k) · Decided

Decided

Cosgrove Edwards Annuloplasty System, Model 4600

K923367510(k) TraditionalDecided Jan 6, 1993181-day reviewClass II21 CFR 870.3800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corp · KRH Ring, Annuloplasty

Cleared on Jan 6, 1993 after a 181-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 14 later devices descend from it.

Decided
Jan 6, 1993
Review
181 days
Class
Class II
Product code
KRH
Recalls
None
Predicates
0

14 later devices descend from it, 6 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared2003: 1 descendant cleared1999: 1 descendant cleared2002: 1 descendant cleared2007: 1 descendant cleared2004: 2 descendants cleared2010: 1 descendant cleared2025: 1 descendant cleared2009: 2 descendants cleared2026: 1 descendant cleared2017: 2 descendants cleared1990200020102020
  1. This deviceK923367 Cosgrove Edwards Annuloplasty System, Model 4600Baxter Healthcare Corp · 1993
  2. Descendant · cites it directly · 10 of its ownK020864 Edwards MC Tricuspid Annuloplasty System, Model 4900Edwards Lifesciences, LLC · 2002
  3. Descendant · cites it directly · 3 of its ownK103520 Carpentier-Edwards Physio Tricuspid Annuloplasty RingEdwards Lifesciences, LLC · 2011
  4. Descendant · cites it directly · 3 of its ownK032250 Geoform Annuloplasty Ring, Mitral Model 4200Edwards Lifesciences, LLC · 2003
  5. Descendant · 2 generations on · 1 of its ownK163608 HAART 300 Aortic Annuloplasty Device 19mm, HAART 300 Aortic…Biostable Science & Engineering, Inc. · 2017
  6. Descendant · cites it directly · 1 of its ownK033685 Northrup Universal Annuloplasty System, Model 1000Medical Cv, Inc. · 2004

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

1999: 12002: 12003: 12004: 22007: 12009: 22010: 12011: 12017: 22025: 12026: 1
1999high 2 (2004) · low 0 (2000)2026

Most influential descendants

Showing 5 of 14 · See all
  • K020864Edwards MC Tricuspid Annuloplasty System, Model 4900Edwards Lifesciences, LLC · 2002 · cites it directly10descendants
  • K103520Carpentier-Edwards Physio Tricuspid Annuloplasty RingEdwards Lifesciences, LLC · 2011 · cites it directly3descendants
  • K032250Geoform Annuloplasty Ring, Mitral Model 4200Edwards Lifesciences, LLC · 2003 · cites it directly3descendants
  • K163608HAART 300 Aortic Annuloplasty Device 19mm, HAART 300 Aortic Annuloplasty Device 21mm…Biostable Science & Engineering, Inc. · 2017 · 2 generations on1descendant
  • K033685Northrup Universal Annuloplasty System, Model 1000Medical Cv, Inc. · 2004 · cites it directly1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K923367Cosgrove Edwards Annuloplasty System, Model 4600Baxter Healthcare Corp1993—
+1K020864Edwards MC Tricuspid Annuloplasty System, Model 4900Edwards Lifesciences, LLC2002—
+1K103520Carpentier-Edwards Physio Tricuspid Annuloplasty RingEdwards Lifesciences, LLC2011—
+1K032250Geoform Annuloplasty Ring, Mitral Model 4200Edwards Lifesciences, LLC2003—
+2K163608HAART 300 Aortic Annuloplasty Device 19mm, HAART 300 Aortic Annuloplasty…Biostable Science & Engineering, Inc.2017—
+1K033685Northrup Universal Annuloplasty System, Model 1000Medical Cv, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200210
200310
200420
200710
200920
201010
201110
201720
202510
202610
FIG. 1 — Lineage of K923367, 1993–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KRH device

  1. #1 K261707 MEMO 4D Curve™ Semirigid mitral annuloplasty…score 12.7 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (14)

See all 14

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K020864Edwards MC Tricuspid Annuloplasty System, Model 4900Edwards Lifesciences, LLC200210
K103520Carpentier-Edwards Physio Tricuspid Annuloplasty RingEdwards Lifesciences, LLC20113
K032250Geoform Annuloplasty Ring, Mitral Model 4200Edwards Lifesciences, LLC20033
K033685Northrup Universal Annuloplasty System, Model 1000Medical Cv, Inc.20041
K071281Uniring - Annuloplasty Ring with SizersPeters Surgical20070
K984435Medtronic Khonsari Annuloplasty Band, Model H609MMedtronic Vascular19990

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K020864 (Edwards Lifesciences, LLC, 2002) has gone furthest, with 10 descendants of its own.

How does its category compare?

All KRH devices

KRH Ring, Annuloplasty: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KRH

4in 2025

2007: 42008: 22009: 82010: 22011: 22014: 12016: 12018: 22019: 22020: 22023: 22024: 12025: 42026 (partial year): 2
2007high 8 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KRH

98in 2025

2007: 90 days median2009: 68 days median2025: 98 days median
2007high 98 (2025) · low 68 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KRH

No recall names KRH since 2007.

Adverse event reports per year · KRH

420in 2025

2007: 2612008: 1,2882009: 9732010: 6302011: 3212012: 902013: 972014: 732015: 1452016: 3472017: 3792018: 3782019: 3492020: 3402021: 4232022: 3722023: 3242024: 4072025: 420
2007high 1,288 (2008) · low 73 (2014)2025

MAUDE reports naming product code KRH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074900261
20082—01,288
20098680973
20102—0630
20112—0321
20120—090
20130—097
20141—073
20150—0145
20161—0347
20170—0379
20182—0378
20192—0349
20202—0340
20210—0423
20220—0372
20232—0324
20241—0407
20254980420
20262—0—
Cite this page

510(k) Report. “K923367: Cosgrove Edwards Annuloplasty System, Model 4600.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K923367

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026