510(k) · Cleared
ClearedHydrogen Spectroscopy Option-Probe #M1040HS/HT
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
GE Medical Systems · LNI System, Nuclear Magnetic Resonance Spectroscopic
Cleared on Apr 25, 1995 after an 826-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 32 later devices descend from it.
- Decided
- Apr 25, 1995
- Review
- 826 days
- Class
- Class II
- Product code
- LNI
- Recalls
- None
- Predicates
- 0
32 later devices descend from it, 5 citing it directly.
- This deviceK930265 Hydrogen Spectroscopy Option-Probe #M1040HS/HTGE Medical Systems · 1995
- Descendant · cites it directly · 21 of its ownK011604 Prostate Spectroscopy and Imaging Exam (Prose) Software Option for MriGe Medical Systems, Inc. · 2001
- Descendant · 2 generations on · 19 of its ownK031350 3TP Software Option3tp, LLC · 2003 · Recalled
- Descendant · 3 generations on · 17 of its ownK041286 Dynacad V1.0Mri Devices Corp. · 2004
- Descendant · 2 generations on · 10 of its ownK050862 3TP Workspace3tp, LLC · 2005 · Recalled
- Descendant · 3 generations on · 9 of its ownK081556 Cadstream, Version 5.0Confirma, Inc. · 2009
Showing 5 of 32 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 32 · See all- K011604Prostate Spectroscopy and Imaging Exam (Prose) Software Option for MriGe Medical Systems, Inc. · 2001 · cites it directly21descendants
- K0313503TP Software Option3tp, LLC · 2003 · 2 generations on19descendants
- K041286Dynacad V1.0Mri Devices Corp. · 2004 · 3 generations on17descendants
- K0508623TP Workspace3tp, LLC · 2005 · 2 generations on10descendants
- K081556Cadstream, Version 5.0Confirma, Inc. · 2009 · 3 generations on9descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K930265 | Hydrogen Spectroscopy Option-Probe #M1040HS/HT | GE Medical Systems | 1995 | — |
| +1 | K011604 | Prostate Spectroscopy and Imaging Exam (Prose) Software Option for Mri | Ge Medical Systems, Inc. | 2001 | — |
| +2 | K031350 | 3TP Software Option | 3tp, LLC | 2003 | 1 |
| +3 | K041286 | Dynacad V1.0 | Mri Devices Corp. | 2004 | — |
| +2 | K050862 | 3TP Workspace | 3tp, LLC | 2005 | 1 |
| +3 | K081556 | Cadstream, Version 5.0 | Confirma, Inc. | 2009 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 1999 | 2 | 0 |
| 2001 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 2 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 4 | 0 |
| 2010 | 1 | 0 |
| 2014 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 2 | 0 |
| 2020 | 2 | 0 |
| 2021 | 2 | 0 |
| 2023 | 1 | 0 |
| 2024 | 3 | 0 |
| 2025 | 1 | 0 |
| 2026 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LNI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (32)
See all 325 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K011604 (Ge Medical Systems, Inc., 2001) has gone furthest, with 21 descendants of its own.
How does its category compare?
All LNI devicesLNI System, Nuclear Magnetic Resonance Spectroscopic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LNI
1in 2010
2026 to Oct 25, outlined.
Median 510(k) review, days · LNI
Too few LNI 510(k)s in any year since 2007 to give a median.
Recalls per year · LNI
12in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LNI
1in 2025
MAUDE reports naming product code LNI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 1 |
| 2012 | 0 | — | 0 | 7 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 1 | 0 |
| 2022 | 0 | — | 0 | 2 |
| 2023 | 0 | — | 4 | 1 |
| 2024 | 0 | — | 12 | 1 |
| 2025 | 0 | — | 0 | 1 |
| 2026 | 0 | — | 0 | — |
https://510kreport.com/device/K930265 · printed Nov 3, 2026
Cite this page
510(k) Report. “K930265: Hydrogen Spectroscopy Option-Probe #M1040HS/HT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K930265
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026