510(k) · Decided
DecidedD-C-S System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Pina-Vertriebs · KWP Appliance, Fixation, Spinal Interlaminal
Cleared on Jun 29, 1994 after a 505-day review. The FDA summary names its predicate without a number.
- Decided
- Jun 29, 1994
- Review
- 505 days
- Class
- Class II
- Product code
- KWP
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Halifax Spinal Clamp System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KWP devicesKWP Appliance, Fixation, Spinal Interlaminal: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWP
9in 2015
2026 to Oct 25, outlined.
Median 510(k) review, days · KWP
113in 2015
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWP
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWP
494in 2025
MAUDE reports naming product code KWP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 96 | 2 | 210 |
| 2008 | 13 | 50 | 1 | 594 |
| 2009 | 12 | 89 | 23 | 682 |
| 2010 | 14 | 186 | 2 | 474 |
| 2011 | 12 | 67 | 6 | 792 |
| 2012 | 18 | 112 | 1 | 918 |
| 2013 | 12 | 99 | 3 | 1,090 |
| 2014 | 13 | 138 | 0 | 1,022 |
| 2015 | 9 | 113 | 1 | 1,348 |
| 2016 | 0 | — | 3 | 1,379 |
| 2017 | 0 | — | 0 | 864 |
| 2018 | 0 | — | 1 | 657 |
| 2019 | 0 | — | 2 | 518 |
| 2020 | 0 | — | 0 | 796 |
| 2021 | 0 | — | 0 | 525 |
| 2022 | 0 | — | 2 | 335 |
| 2023 | 0 | — | 0 | 332 |
| 2024 | 0 | — | 0 | 436 |
| 2025 | 0 | — | 0 | 494 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The D-C-S System is intended for use in the treatment of fracture, deformity, spondylolisthesis, spinal stenosis, tumors and metastases, spondylitis, and spine. It is intended for use in stabilization of the cervical spine (C1-C7) multi-operated using a posterior surgical approach. The implant is intended to be removed from the cervical spine once stabilization or correction is achieved.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K930657 · printed Nov 6, 2026
Cite this page
510(k) Report. “K930657: D-C-S System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K930657
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026