510(k) · Cleared
ClearedFoundation Posterior Stabilized Knee
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Encore Orthopedics, Inc. · JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Cleared on Nov 8, 1994 after a 475-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 74 later devices descend from it.
- Decided
- Nov 8, 1994
- Review
- 475 days
- Class
- Class II
- Product code
- JWH
- Recalls
- None
- Predicates
- 0
74 later devices descend from it, 8 citing it directly.
- This deviceK933539 Foundation Posterior Stabilized KneeEncore Orthopedics, Inc. · 1994
- Descendant · cites it directly · 72 of its ownK100900 Motivation Knee SystemEncore Medical L.P. · 2010 · Recalled
- Descendant · 2 generations on · 35 of its ownK113756 Highly Cross Linked VE Central Peg Patella Highly Cross Linked VE…Encore Medical L.P. · 2012 · Recalled
- Descendant · 3 generations on · 33 of its ownK122870 Itotal Cruciate Retaining (CR) Knee Replacement SystemConformis, Inc. · 2013
- Descendant · 4 generations on · 30 of its ownK131467 Itotal Cruciate Retaining (CR) Knee Replacement SystemConformis, Inc. · 2013
- Descendant · 4 generations on · 30 of its ownK131019 Itotal Cruciate Retaining (C) Knee Replacement SystemConformis, Inc. · 2013
Showing 5 of 74 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 74 · See all- K100900Motivation Knee SystemEncore Medical L.P. · 2010 · cites it directly72descendants
- K113756Highly Cross Linked VE Central Peg Patella Highly Cross Linked VE Tri-Peg Patella Highly…Encore Medical L.P. · 2012 · 2 generations on35descendants
- K122870Itotal Cruciate Retaining (CR) Knee Replacement SystemConformis, Inc. · 2013 · 3 generations on33descendants
- K131467Itotal Cruciate Retaining (CR) Knee Replacement SystemConformis, Inc. · 2013 · 4 generations on30descendants
- K131019Itotal Cruciate Retaining (C) Knee Replacement SystemConformis, Inc. · 2013 · 4 generations on30descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K933539 | Foundation Posterior Stabilized Knee | Encore Orthopedics, Inc. | 1994 | — |
| +1 | K100900 | Motivation Knee System | Encore Medical L.P. | 2010 | 4 |
| +2 | K113756 | Highly Cross Linked VE Central Peg Patella Highly Cross Linked VE Tri-Peg… | Encore Medical L.P. | 2012 | 1 |
| +3 | K122870 | Itotal Cruciate Retaining (CR) Knee Replacement System | Conformis, Inc. | 2013 | — |
| +4 | K131467 | Itotal Cruciate Retaining (CR) Knee Replacement System | Conformis, Inc. | 2013 | — |
| +4 | K131019 | Itotal Cruciate Retaining (C) Knee Replacement System | Conformis, Inc. | 2013 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 1 | 0 |
| 2010 | 1 | 0 |
| 2012 | 3 | 0 |
| 2013 | 5 | 0 |
| 2014 | 7 | 0 |
| 2015 | 2 | 0 |
| 2016 | 8 | 0 |
| 2017 | 2 | 0 |
| 2018 | 3 | 0 |
| 2019 | 4 | 0 |
| 2020 | 5 | 0 |
| 2021 | 14 | 0 |
| 2022 | 5 | 0 |
| 2023 | 8 | 0 |
| 2025 | 5 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JWH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JWH device
- #1 K221479 Persona Personalized Knee Systemscore 22.4 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (74)
See all 748 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K100900 | Motivation Knee System | 2010 | 72 |
| K122239 | Foundation Knee System with Tinbn Coating Foundation PS Knee System with Tinbn Coating… | 2013 | 20 |
| K143242 | Rebel 3DKNEE System | 2015 | 11 |
| K182872 | LINK GEMINI SL Total Knee System | 2019 | 8 |
| K140830 | Exprt Revision Knee | 2014 | 7 |
| K160342 | EMPOWR PS Knee System | 2016 | 6 |
| K180930 | Empowr VVC Tibial Insert | 2018 | 3 |
| K963028 | Tibial Insert | 1996 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K100900 (Encore Medical L.P., 2010) has gone furthest, with 72 descendants of its own.
How does its category compare?
All JWH devicesJWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JWH
20in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JWH
55in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JWH
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JWH
9,306in 2025
MAUDE reports naming product code JWH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 74 | 14 | 1,305 |
| 2008 | 17 | 81 | 10 | 1,483 |
| 2009 | 11 | 168 | 109 | 1,870 |
| 2010 | 19 | 85 | 32 | 3,286 |
| 2011 | 25 | 87 | 27 | 5,133 |
| 2012 | 33 | 85 | 85 | 5,203 |
| 2013 | 31 | 128 | 31 | 6,135 |
| 2014 | 33 | 98 | 13 | 6,722 |
| 2015 | 27 | 87 | 11 | 6,881 |
| 2016 | 18 | 88 | 17 | 7,586 |
| 2017 | 25 | 118 | 61 | 12,263 |
| 2018 | 25 | 90 | 14 | 14,071 |
| 2019 | 28 | 133 | 5 | 14,987 |
| 2020 | 22 | 59 | 2 | 12,592 |
| 2021 | 24 | 61 | 8 | 9,408 |
| 2022 | 17 | 56 | 12 | 8,364 |
| 2023 | 20 | 57 | 67 | 8,947 |
| 2024 | 19 | 89 | 7 | 10,828 |
| 2025 | 20 | 55 | 2 | 9,306 |
| 2026 | 12 | 63 | 4 | — |
https://510kreport.com/device/K933539 · printed Nov 4, 2026
Cite this page
510(k) Report. “K933539: Foundation Posterior Stabilized Knee.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K933539
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026