510(k) · Cleared
ClearedDried Gram-Positive Mic/Combo Panels
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Baxter Diagnostics, Inc. · JWY Manual Antimicrobial Susceptibility Test Systems
Cleared on Jul 18, 1995 after a 673-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
- Decided
- Jul 18, 1995
- Review
- 673 days
- Class
- Class II
- Product code
- JWY
- Recalls
- None
- Predicates
- 0
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JWY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JWY device
- #1 K260447 ETEST Gepotidacin (GEP) (0.016-256 µg/mL)score 12.7 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JWY devicesJWY Manual Antimicrobial Susceptibility Test Systems: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JWY
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JWY
106in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JWY
31in 2022
Class I (13 since 2007) Class II/III not classified
Adverse event reports per year · JWY
1in 2024
MAUDE reports naming product code JWY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 6 | 85 | 1 | 1 |
| 2009 | 2 | — | 0 | 1 |
| 2010 | 4 | 73 | 0 | 0 |
| 2011 | 4 | 125 | 3 | 0 |
| 2012 | 1 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 6 | 106 | 5 | 4 |
| 2015 | 9 | 90 | 6 (4) | 11 |
| 2016 | 4 | 88 | 0 | 20 |
| 2017 | 14 | 61 | 2 | 9 |
| 2018 | 12 | 51 | 0 | 13 |
| 2019 | 18 | 60 | 0 | 10 |
| 2020 | 5 | 66 | 0 | 20 |
| 2021 | 5 | 266 | 0 | 41 |
| 2022 | 0 | — | 31 (9) | 11 |
| 2023 | 7 | 85 | 0 | 9 |
| 2024 | 6 | 90 | 0 | 1 |
| 2025 | 14 | 106 | 0 | 0 |
| 2026 | 2 | — | 0 | — |
https://510kreport.com/device/K934458 · printed Nov 4, 2026
Cite this page
510(k) Report. “K934458: Dried Gram-Positive Mic/Combo Panels.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K934458
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Page last updated Nov 3, 2026