510(k) · Cleared
Recalled · Class II · 2014Synthes 2.7 MM Cannulated Screw and Threaded Washer
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Synthes (Usa) · HWC Screw, Fixation, Bone
Cleared on Jun 16, 1995 after an 86-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 2 later devices descend from it. It has been recalled once.
- Decided
- Jun 16, 1995
- Review
- 86 days
- Class
- Class II
- Product code
- HWC
- Recalls
- 1
- Predicates
- 0
2 later devices descend from it, 1 citing it directly.
- This deviceK951304 Synthes 2.7 MM Cannulated Screw and Threaded WasherSynthes (Usa) · 1995
- Descendant · cites it directly · 1 of its ownK191118 Avanti Distal Radius and Forearm SystemAvanti Orthopaedics, Inc. · 2019
- Descendant · 2 generations on · 0 of its ownK261145 Avanti Distal Elbow ORIF SystemAvanti Orthopaedics, LLC · 2026
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K951304 | Synthes 2.7 MM Cannulated Screw and Threaded Washer | Synthes (Usa) | 1995 | — |
| +1 | K191118 | Avanti Distal Radius and Forearm System | Avanti Orthopaedics, Inc. | 2019 | — |
| +2 | K261145 | Avanti Distal Elbow ORIF System | Avanti Orthopaedics, LLC | 2026 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2019 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HWC device
- #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K191118 | Avanti Distal Radius and Forearm System | 2019 | 1 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 30, 2014 | Class II | Z-2265-2014 | Employee error | A screw set was returned from the field for destruction after being exposed to flood water, which was erroneously reprocessed and returned to the field. Initial investigative testing indicated the components within the set may be cytotoxic. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K191118 (Avanti Orthopaedics, Inc., 2019) has gone furthest, with 1 descendant of its own.
How does its category compare?
All HWC devicesHWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HWC
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HWC
111in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HWC
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HWC
2,893in 2025
MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 77 | 25 | 669 |
| 2008 | 33 | 76 | 33 | 660 |
| 2009 | 27 | 113 | 29 | 651 |
| 2010 | 23 | 110 | 7 | 765 |
| 2011 | 35 | 88 | 12 | 1,104 |
| 2012 | 20 | 99 | 30 | 3,339 |
| 2013 | 25 | 90 | 14 | 3,850 |
| 2014 | 31 | 88 | 2 | 2,549 |
| 2015 | 41 | 85 | 5 | 2,711 |
| 2016 | 26 | 131 | 4 | 2,285 |
| 2017 | 40 | 127 | 4 | 2,561 |
| 2018 | 20 | 106 | 1 | 3,662 |
| 2019 | 30 | 108 | 5 | 5,463 |
| 2020 | 28 | 75 | 4 | 4,820 |
| 2021 | 26 | 84 | 2 | 4,446 |
| 2022 | 26 | 167 | 13 | 3,934 |
| 2023 | 24 | 104 | 0 | 3,718 |
| 2024 | 17 | 90 | 0 | 3,575 |
| 2025 | 15 | 111 | 1 | 2,893 |
| 2026 | 21 | 125 | 2 | — |
https://510kreport.com/device/K951304 · printed Nov 6, 2026
Cite this page
510(k) Report. “K951304: Synthes 2.7 MM Cannulated Screw and Threaded Washer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K951304
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026