510(k) · Cleared
ClearedMiniboneplate System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ace Surgical Supply Co., Inc. · JEY Plate, Bone
Cleared on May 5, 1995 after a 45-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 144 later devices descend from it.
- Decided
- May 5, 1995
- Review
- 45 days
- Class
- Class II
- Product code
- JEY
- Recalls
- None
- Predicates
- 0
144 later devices descend from it, 4 citing it directly.
- This deviceK951392 Miniboneplate SystemAce Surgical Supply Co., Inc. · 1995
- Descendant · cites it directly · 135 of its ownK073343 Ace Surgical Secure-Mini Implant System, Model 09-270X-XXAce Surgical Supply Co., Inc. · 2008
- Descendant · 2 generations on · 134 of its ownK092594 Ace Surgical Secure- Mini Locator Implant System, Model 09-2702-OX…Ace Surgical Supply Co., Inc. · 2009
- Descendant · 2 generations on · 127 of its ownK123022 Neodent Implant SystemJjgc Industria E Comercio DE Materiais Dentarios S · 2013
- Descendant · 3 generations on · 123 of its ownK133510 Neodent Implant SystemJj Industria E Comercio DE Materiais Dentarios SA · 2014
- Descendant · 3 generations on · 109 of its ownK133592 Neodent Implant System, Titamax TI EX Acqua and TI Drive Acqua…Neodent USA, Inc. · 2014
Showing 5 of 144 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 144 · See all- K073343Ace Surgical Secure-Mini Implant System, Model 09-270X-XXAce Surgical Supply Co., Inc. · 2008 · cites it directly135descendants
- K092594Ace Surgical Secure- Mini Locator Implant System, Model 09-2702-OX, 09-2703-OX, 09-2705-OXAce Surgical Supply Co., Inc. · 2009 · 2 generations on134descendants
- K123022Neodent Implant SystemJjgc Industria E Comercio DE Materiais Dentarios S · 2013 · 2 generations on127descendants
- K133510Neodent Implant SystemJj Industria E Comercio DE Materiais Dentarios SA · 2014 · 3 generations on123descendants
- K133592Neodent Implant System, Titamax TI EX Acqua and TI Drive Acqua, Titamax Smart EX Acqua…Neodent USA, Inc. · 2014 · 3 generations on109descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K951392 | Miniboneplate System | Ace Surgical Supply Co., Inc. | 1995 | — |
| +1 | K073343 | Ace Surgical Secure-Mini Implant System, Model 09-270X-XX | Ace Surgical Supply Co., Inc. | 2008 | — |
| +2 | K092594 | Ace Surgical Secure- Mini Locator Implant System, Model 09-2702-OX… | Ace Surgical Supply Co., Inc. | 2009 | — |
| +2 | K123022 | Neodent Implant System | Jjgc Industria E Comercio DE Materiais Dentarios S | 2013 | — |
| +3 | K133510 | Neodent Implant System | Jj Industria E Comercio DE Materiais Dentarios SA | 2014 | — |
| +3 | K133592 | Neodent Implant System, Titamax TI EX Acqua and TI Drive Acqua, Titamax Smart… | Neodent USA, Inc. | 2014 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 2 | 0 |
| 2009 | 1 | 0 |
| 2010 | 2 | 0 |
| 2011 | 1 | 0 |
| 2012 | 2 | 0 |
| 2013 | 2 | 0 |
| 2014 | 4 | 0 |
| 2015 | 4 | 0 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 6 | 0 |
| 2019 | 9 | 0 |
| 2020 | 12 | 0 |
| 2021 | 13 | 0 |
| 2022 | 14 | 0 |
| 2023 | 17 | 0 |
| 2024 | 14 | 0 |
| 2025 | 24 | 0 |
| 2026 | 12 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JEY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JEY device
- #1 K252246 Leforte MMF Systemscore 15.6 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it? (144)
See all 1444 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K073343 (Ace Surgical Supply Co., Inc., 2008) has gone furthest, with 135 descendants of its own.
How does its category compare?
All JEY devicesJEY Plate, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JEY
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JEY
159in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JEY
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JEY
1,003in 2025
MAUDE reports naming product code JEY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 9 | 115 | 0 | 29 |
| 2008 | 7 | 84 | 3 | 24 |
| 2009 | 4 | 121 | 6 | 93 |
| 2010 | 6 | 199 | 85 | 215 |
| 2011 | 5 | 75 | 0 | 241 |
| 2012 | 10 | 194 | 0 | 428 |
| 2013 | 8 | 126 | 1 | 766 |
| 2014 | 6 | 223 | 0 | 616 |
| 2015 | 7 | 160 | 0 | 767 |
| 2016 | 1 | — | 0 | 558 |
| 2017 | 5 | 190 | 0 | 568 |
| 2018 | 7 | 255 | 0 | 608 |
| 2019 | 6 | 163 | 0 | 595 |
| 2020 | 6 | 198 | 1 | 680 |
| 2021 | 4 | 299 | 0 | 451 |
| 2022 | 5 | 135 | 0 | 344 |
| 2023 | 2 | — | 0 | 495 |
| 2024 | 5 | 159 | 0 | 696 |
| 2025 | 2 | — | 0 | 1,003 |
| 2026 | 3 | 258 | 0 | — |
https://510kreport.com/device/K951392 · printed Nov 4, 2026
Cite this page
510(k) Report. “K951392: Miniboneplate System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K951392
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026