510(k) Report

510(k) · Cleared

Cleared

Visuwell Reagin II

K952802510(k) TraditionalCleared May 23, 1996339-day reviewClass II21 CFR 866.3820

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomira Diagnostics, Inc. · GMQ Antigens, Nontreponemal, All

Cleared on May 23, 1996 after a 339-day review. The FDA summary names its predicate without a number.

Decided
May 23, 1996
Review
339 days
Class
Class II
Product code
GMQ
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K952802Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GMQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GMQ device

  1. #1 K250249 Gold Standard Diagnostics (GSD) AIX1000 Rapid…score 10.7 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Venereal Disease Research Laboratory (VDRL) Slide Test
Named without a submission number
—
*—Rapid Plasma Reagin (RPR) Card Test
Named without a submission number
—
*—Reagin Screen Test (RST)
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All GMQ devices

GMQ Antigens, Nontreponemal, All: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GMQ

1in 2025

2015: 12018: 22020: 12025: 1
2007high 2 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GMQ

Too few GMQ 510(k)s in any year since 2007 to give a median.

Recalls per year · GMQ

No recall names GMQ since 2007.

Adverse event reports per year · GMQ

2in 2024

2007: 32008: 22011: 12017: 12021: 32022: 142023: 62024: 2
2007high 14 (2022) · low 0 (2009)2025

MAUDE reports naming product code GMQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20080—02
20090—00
20100—00
20110—01
20120—00
20130—00
20140—00
20151—00
20160—00
20170—01
20182—00
20190—00
20201—00
20210—03
20220—014
20230—06
20240—02
20251—00
20260—0—

What is it indicated for?

Visuwell® Reagin II is an enzyme-linked immunosorbent assay for the in vitro qualitative detection of non-treponemal (reagin) antibodies as a screening test in syphilis serology. It is not intended for use in screening blood or plasma donors.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K952802: Visuwell Reagin II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K952802

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026