510(k) · Cleared
ClearedAlternate Sterlization Process & Modified DF-1 Lead Connector (Modification)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medtronic Vascular · DXY Implantable Pacemaker Pulse-Generator
Cleared on Dec 15, 1995 after a 127-day review. FDA has not posted a summary or statement for it, so its predicates are not known.
- Decided
- Dec 15, 1995
- Review
- 127 days
- Class
- Class III
- Product code
- DXY
- Recalls
- None
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DXY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All DXY devicesDXY Implantable Pacemaker Pulse-Generator: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DXY
19in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DXY
Too few DXY 510(k)s in any year since 2007 to give a median.
Recalls per year · DXY
4in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DXY
810in 2025
MAUDE reports naming product code DXY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 2,407 |
| 2008 | 0 | — | 0 | 2,649 |
| 2009 | 0 | — | 6 | 3,750 |
| 2010 | 0 | — | 1 | 4,187 |
| 2011 | 0 | — | 2 | 6,050 |
| 2012 | 0 | — | 0 | 3,709 |
| 2013 | 0 | — | 0 | 2,682 |
| 2014 | 0 | — | 0 | 5,604 |
| 2015 | 0 | — | 0 | 1,022 |
| 2016 | 15 | — | 0 | 542 |
| 2017 | 51 | — | 4 | 1,047 |
| 2018 | 45 | — | 0 | 2,070 |
| 2019 | 19 | — | 0 | 1,799 |
| 2020 | 23 | — | 0 | 546 |
| 2021 | 20 | — | 0 | 560 |
| 2022 | 14 | — | 0 | 784 |
| 2023 | 19 | — | 0 | 922 |
| 2024 | 20 | — | 0 | 773 |
| 2025 | 19 | — | 0 | 810 |
| 2026 | 19 | — | 0 | — |
https://510kreport.com/device/K954092 · printed Nov 4, 2026
Cite this page
510(k) Report. “K954092: Alternate Sterlization Process & Modified DF-1 Lead Connector (Modification).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K954092
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Page last updated Nov 3, 2026