510(k) Report

510(k) · Cleared

Cleared

3M Model 1860 Health Care Particulate Respirator Type N95

K955382510(k) TraditionalCleared May 1, 1996159-day reviewClass II21 CFR 878.4040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

3M Company · FXX Mask, Surgical

Cleared on May 1, 1996 after a 159-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.

Decided
May 1, 1996
Review
159 days
Class
Class II
Product code
FXX
Recalls
None
Predicates
0

2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 1997: 2 descendants cleared1995200020052010201520202025
  1. This deviceK955382 3M Model 1860 Health Care Particulate Respirator Type N953M Company · 1996
  2. Descendant · cites it directly · 0 of its ownK964723 Racal N95 ResiratorRacal Filter Technologies, Inc. · 1997
  3. Descendant · cites it directly · 0 of its ownK964722 Delta N95 RespiratorRacal Filter Technologies, Inc. · 1997

Most influential descendants

Showing 2 of 2 · See all
  • K964723Racal N95 ResiratorRacal Filter Technologies, Inc. · 1997 · cites it directly0descendants
  • K964722Delta N95 RespiratorRacal Filter Technologies, Inc. · 1997 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K9553823M Model 1860 Health Care Particulate Respirator Type N953M Company1996—
+1K964723Racal N95 ResiratorRacal Filter Technologies, Inc.1997—
+1K964722Delta N95 RespiratorRacal Filter Technologies, Inc.1997—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199720
FIG. 1 — Lineage of K955382, 1996–1997Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FXX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FXX device

  1. #1 K201479 DemeMASKscore 40.2 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—3M Model 1812 surgical mask
Named without a submission number
—
*—Tecnol DMR2010 respirator
Named without a submission number
—
*—Lazer™ Surgical Mask
Named without a submission number
—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K964723Racal N95 ResiratorRacal Filter Technologies, Inc.19970
K964722Delta N95 RespiratorRacal Filter Technologies, Inc.19970

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K964723 (Racal Filter Technologies, Inc., 1997) has gone furthest, with 0 descendants of its own.

How does its category compare?

All FXX devices

FXX Mask, Surgical: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FXX

6in 2025

2007: 22008: 22009: 12010: 72011: 62012: 12013: 32014: 12015: 52016: 52017: 12018: 32019: 42020: 272021: 2182022: 912023: 222024: 152025: 62026 (partial year): 5
2007high 218 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FXX

123in 2025

2010: 144 days median2011: 137 days median2013: 219 days median2015: 298 days median2016: 268 days median2018: 119 days median2019: 124 days median2020: 113 days median2021: 162 days median2022: 113 days median2023: 139 days median2024: 263 days median2025: 123 days median2026 (partial year): 142 days median
2007high 298 (2015) · low 113 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FXX

2in 2024

2019: 22023: 12024: 2
2007high 2 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FXX

11in 2025

2007: 112008: 102009: 32010: 92011: 82012: 222013: 92014: 52015: 142016: 162017: 452018: 212019: 232020: 602021: 672022: 212023: 212024: 212025: 11
2007high 67 (2021) · low 3 (2009)2025

MAUDE reports naming product code FXX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—011
20082—010
20091—03
2010714409
2011613708
20121—022
2013321909
20141—05
20155298014
20165268016
20171—045
20183119021
20194124223
202027113060
2021218162067
202291113021
202322139121
202415263221
20256123011
202651420—

What is it indicated for?

Meets the CDC guidelines for TB exposure control

Has a filter efficiency level of 95% or greater against particulate aerosols free of oil (Type N95 respirator)

Minimizes wearer exposure to certain airborne particles in a size range of 0.1 to 10.0 microns, such as those generated by electrocautery, laser, and other powered medical instruments

Designed to be fluid resistant to splash and spatter of blood and body fluids and other potentially hazardous biomaterials

Provides greater than 999 Racicrial Filtration Efficiency* to exhaied wearer generated microorganisims (*as determined by the modified Greene and Vesley test meihod)

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K955382: 3M Model 1860 Health Care Particulate Respirator Type N95.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K955382

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026