510(k) Report

510(k) · Cleared

Cleared

Vidas Chlamydia Blocking Assay

K955627510(k) TraditionalCleared Oct 7, 1996301-day reviewClass I21 CFR 866.3120

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomerieux Vitek, Inc. · LJC Enzyme Linked Immunoabsorbent Assay, (Chlamydiae Group)

Cleared on Oct 7, 1996 after a 301-day review. The FDA summary names its predicate without a number.

Decided
Oct 7, 1996
Review
301 days
Class
Class I
Product code
LJC
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K955627Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LJC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—cell culture
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All LJC devices

LJC Enzyme Linked Immunoabsorbent Assay, (Chlamydiae Group): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LJC

FDA has decided no LJC device since 2007.

Median 510(k) review, days · LJC

Too few LJC 510(k)s in any year since 2007 to give a median.

Recalls per year · LJC

1in 2025

2008: 22011: 12025: 1
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LJC

1in 2019

2018: 22019: 1
2007high 2 (2018) · low 0 (2007)2025

MAUDE reports naming product code LJC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—20
20090—00
20100—00
20110—10
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—02
20190—01
20200—00
20210—00
20220—00
20230—00
20240—00
20250—10
20260—0—

What is it indicated for?

The VIDAS Chlamydia Blocking (CHB) assay used as a supplemental test to verify positive and equivocal results from female endocervical and male urtheral specimens in the VIDAS Chlamydia (CHL) assay and is substantially equivalent to cell culture for the qualitative detection of Chlamydia antigen.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K955627: Vidas Chlamydia Blocking Assay.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K955627

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026