510(k) Report

510(k) · Cleared

Cleared

Cofied Modular Shoulder System

K955767510(k) TraditionalCleared Apr 8, 1996109-day reviewClass II21 CFR 888.3660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Smith & Nephew Richards, Inc. · KWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented

Cleared on Apr 8, 1996 after a 109-day review. The FDA summary names its predicate without a number. 29 later devices descend from it.

Decided
Apr 8, 1996
Review
109 days
Class
Class II
Product code
KWS
Recalls
None
Predicates
0

29 later devices descend from it, 5 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2010: 2 descendants cleared2012: 3 descendants cleared2007: 1 descendant cleared2011: 2 descendants cleared2023: 4 descendants cleared2022: 2 descendants cleared2026: 2 descendants cleared2019: 2 descendants cleared2015: 1 descendant cleared2018: 3 descendants cleared2016: 2 descendants cleared2025: 3 descendants cleared2024: 1 descendant cleared1995200020052010201520202025
  1. This deviceK955767 Cofied Modular Shoulder SystemSmith & Nephew Richards, Inc. · 1996
  2. Descendant · cites it directly · 26 of its ownK070565 Cofield Total Shoulder SystemSmith & Nephew, Inc. · 2007
  3. Descendant · cites it directly · 24 of its ownK093430 Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech…Exactech, Inc. · 2010 · Recalled
  4. Descendant · 2 generations on · 22 of its ownK103419 Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc. · 2010 · Recalled
  5. Descendant · 3 generations on · 21 of its ownK111379 Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium…Exactech, Inc. · 2011 · Recalled
  6. Descendant · 4 generations on · 20 of its ownK121220 Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small…Exactech, Inc. · 2012 · Recalled

Showing 5 of 29 descendants. See all descendants

Descendants cleared per year

2003: 12007: 12010: 22011: 22012: 32015: 12016: 22018: 32019: 22022: 22023: 42024: 12025: 32026: 2
2003high 4 (2023) · low 0 (2004)2026

Most influential descendants

Showing 5 of 29 · See all
  • K070565Cofield Total Shoulder SystemSmith & Nephew, Inc. · 2007 · cites it directly26descendants
  • K093430Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage, Glenoid…Exactech, Inc. · 2010 · cites it directly24descendants
  • K103419Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc. · 2010 · 2 generations on22descendants
  • K111379Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium / Large /…Exactech, Inc. · 2011 · 3 generations on21descendants
  • K121220Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/RightExactech, Inc. · 2012 · 4 generations on20descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K955767Cofied Modular Shoulder SystemSmith & Nephew Richards, Inc.1996—
+1K070565Cofield Total Shoulder SystemSmith & Nephew, Inc.2007—
+1K093430Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage…Exactech, Inc.20101
+2K103419Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc.20102
+3K111379Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium / Large /…Exactech, Inc.20112
+4K121220Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/RightExactech, Inc.20122

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200710
201020
201120
201230
201510
201620
201830
201920
202220
202340
202410
202530
202620
FIG. 1 — Lineage of K955767, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWS device

  1. #1 K220847 AETOS Shoulder Systemscore 21.1 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (6)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Biomet Biomodular Total Shoulder
Named without a submission number
—
*—DePuy Global Total Shoulder
Named without a submission number
—
*—Orthomet 3M Neer II and Modular Shoulder
Named without a submission number
—
*—Zimmer Fenlin Total Shoulder
Named without a submission number
—
*—Kirschner Modular I-C
Named without a submission number
—
*—Intermedics Select Shoulder System
Named without a submission number
—

What descends from it? (29)

See all 29

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070565Cofield Total Shoulder SystemSmith & Nephew, Inc.200726
K093430Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage, Glenoid…Exactech, Inc.201024
K121714Smith & Nephew, Inc. Shoulder System InstrumentsSmith & Nephew, Inc.20120
K113012Promos Modular Shoulder SystemSmith & Nephew, Inc.20120
K030344Modular Neer 3 Humeral Stems and Modular Neer 3 Humeral HeadsSmith & Nephew, Inc.20030

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K070565 (Smith & Nephew, Inc., 2007) has gone furthest, with 26 descendants of its own.

How does its category compare?

All KWS devices

KWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWS

3in 2025

2007: 22008: 42009: 42010: 72011: 112012: 72013: 122014: 72015: 82016: 102017: 72018: 42019: 92020: 32021: 52022: 52023: 42024: 22025: 32026 (partial year): 2
2007high 12 (2013) · low 2 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWS

97in 2025

2008: 37 days median2009: 108 days median2010: 33 days median2011: 90 days median2012: 86 days median2013: 120 days median2014: 89 days median2015: 129 days median2016: 114 days median2017: 120 days median2018: 152 days median2019: 106 days median2020: 98 days median2021: 151 days median2022: 158 days median2023: 250 days median2025: 97 days median
2007high 250 (2023) · low 33 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWS

2in 2023

2007: 212008: 292010: 102011: 112012: 102014: 12016: 12017: 42018: 12019: 22020: 52023: 22026 (partial year): 1
2007high 29 (2008) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWS

2,281in 2025

2007: 1582008: 2382009: 2942010: 3932011: 4862012: 5422013: 8182014: 1,0662015: 1,1702016: 9702017: 1,6812018: 1,5452019: 1,7282020: 1,5672021: 1,3582022: 1,2682023: 1,7502024: 2,1222025: 2,281
2007high 2,281 (2025) · low 158 (2007)2025

MAUDE reports naming product code KWS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—21158
200843729238
200941080294
201073310393
2011119011486
201278610542
2013121200818
201478911,066
2015812901,170
2016101141970
2017712041,681
2018415211,545
2019910621,728
202039851,567
2021515101,358
2022515801,268
2023425021,750
20242—02,122
202539702,281
20262—1—

What is it indicated for?

The Cofield Modular Shoulder System is indicated for the following use: Proximal Humeral Prosthesis 1. Complex, acute fractures or fracture-dislocations of the humeral head (e.g., the four-part injuries in the Neer classification, or headsplitting, or head impression fractures). 2. Complex, chronic fractures or fracture-dislocations of the humeral head with malunion, nonunion of a small osteoporotic head fragment, or chronic dislocation with loss of…

Read the full statement (160 words)

The Cofield Modular Shoulder System is indicated for the following use:

Proximal Humeral Prosthesis

1. Complex, acute fractures or fracture-dislocations of the humeral head (e.g., the four-part injuries in the Neer classification, or headsplitting, or head impression fractures).

2. Complex, chronic fractures or fracture-dislocations of the humeral head with malunion, nonunion of a small osteoporotic head fragment, or chronic dislocation with loss of humeral head cartilage, or large impression fractures.

3. Avascular necrosis with intact glenoid cartilage.

4. Selected patients with arthritis who do not have adequate scapular bone to support a glenoid component or who must engage in moderately heavy activities.

Total Shoulder Arthroplasty

Severe destruction of the glenohumeral articular surfaces with intractable chronic pain in rheumatoid arthritis, juvenile rheumatoid arthritis, osteoarthritis, traumatic arthritis, cuff tear arthroplasty, ancient septic arthritis, avascular necrosis with secondary glenoid changes, radiation necrosis, and other failed reconstructive procedures.

The device is intended only for use with bone cement and is a single use device.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K955767: Cofied Modular Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K955767

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026