510(k) Report

510(k) · Cleared

Cleared

Circon-Surgitek Classic Double Pigtail Ureteral Stent

K960148510(k) TraditionalCleared Mar 25, 199674-day reviewClass II21 CFR 876.4620

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cabot Medical Corp. · FAD Stent, Ureteral

Cleared on Mar 25, 1996 as substantially equivalent to K860267 (Van-Tec, Inc., 1986) and 3 other predicates after a 74-day review. Its family tree reaches back 1 generation to 1986.

Decided
Mar 25, 1996
Review
74 days
Class
Class II
Product code
FAD
Recalls
None
Predicates
4

Its longest line of descent runs back 1 generation to K860267 (1986). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1995: 1 other ancestor1994: 1 other ancestor1991: 1 other ancestorReference device: K913928 · Surgitek (R) 4.5FR Lubri-Flex (TM) Ureteral Stent · Surgitek Medical Engineering Corp. · 1991K860267 · Mardis Dangler Ureteral Stent Set · Van-Tec, Inc. · 1986 · recalled1986198819901992199419961998
Other ancestors, by generation 1 generation back: 3 other ancestors K860267 · Mardis Dangler Ureteral Stent Set · Van-Tec, Inc. · 1986 · recalled0
  1. Root · 1 generation backK860267 Mardis Dangler Ureteral Stent SetVan-Tec, Inc. · 1986 · Recalled
  2. This deviceK960148 Circon-Surgitek Classic Double Pigtail Ureteral StentCabot Medical Corp. · 1996
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K860267Mardis Dangler Ureteral Stent SetVan-Tec, Inc.19861
0 (this device)K960148Circon-Surgitek Classic Double Pigtail Ureteral StentCabot Medical Corp.1996—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199410
199510
FIG. 1 — Lineage of K960148, 1986–1996Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FAD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FAD device

  1. #1 K251890 Disposable Ureteral Stentsscore 12.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K860267Mardis Dangler Ureteral Stent Set
Summary page 1
…quivalent by the US FDA. The Circon-Surgitek Classic Double Pigtail Ureteral Stent is substantially equivalent to the following devices; 1) the Microvasive Mardis Stent [K860267), 2) the Cook Double Pigtail Stent [K930731]; 3) the Circon-Surgitek Lubri-Flex [K905289] and 4) the Circon-Surgitek Quadra-Coil™…
Van-Tec, Inc.19861
*K930731Slip-Coat Stents
Summary page 1
…Classic Double Pigtail Ureteral Stent is substantially equivalent to the following devices; 1) the Microvasive Mardis Stent [K860267), 2) the Cook Double Pigtail Stent [K930731]; 3) the Circon-Surgitek Lubri-Flex [K905289] and 4) the Circon-Surgitek Quadra-Coil™ [K946296]. fi iveness : Cj…
Cook Urological, Inc.1994—
*K905289Surgitek (R) Lubri-Flex (TM) Ureteral Stent
Summary page 1
…stantially equivalent to the following devices; 1) the Microvasive Mardis Stent [K860267), 2) the Cook Double Pigtail Stent [K930731]; 3) the Circon-Surgitek Lubri-Flex [K905289] and 4) the Circon-Surgitek Quadra-Coil™ [K946296]. fi iveness : Cj - itek Double Pigtail Ureteral Stent Device…
Medical Engineering Corp.1991—
*K946296Quadra-Coil Ureteral Stent
Summary page 1
…the Microvasive Mardis Stent [K860267), 2) the Cook Double Pigtail Stent [K930731]; 3) the Circon-Surgitek Lubri-Flex [K905289] and 4) the Circon-Surgitek Quadra-Coil™ [K946296]. fi iveness : Cj - itek Double Pigtail Ureteral Stent Device Description and Intended Use of the Marketed Devic…
Surgitek1995—
†K913928Surgitek (R) 4.5FR Lubri-Flex (TM) Ureteral StentSurgitek Medical Engineering Corp.1991—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All FAD devices

FAD Stent, Ureteral: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FAD

4in 2025

2007: 12008: 12010: 12014: 12016: 42017: 82018: 92019: 52020: 12021: 22022: 52024: 12025: 42026 (partial year): 1
2007high 9 (2018) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FAD

186in 2025

2016: 143 days median2017: 266 days median2018: 258 days median2019: 263 days median2022: 143 days median2025: 186 days median
2007high 266 (2017) · low 143 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FAD

4in 2025

2007: 12008: 222009: 22010: 12016: 42019: 62020: 22021: 12022: 92025: 4
2007high 22 (2008) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FAD

634in 2025

2007: 432008: 762009: 1232010: 782011: 952012: 1312013: 822014: 782015: 1302016: 1822017: 2652018: 2772019: 2612020: 3522021: 5312022: 5592023: 6912024: 6032025: 634
2007high 691 (2023) · low 43 (2007)2025

MAUDE reports naming product code FAD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—143
20081—2276
20090—2123
20101—178
20110—095
20120—0131
20130—082
20141—078
20150—0130
201641434182
201782660265
201892580277
201952636261
20201—2352
20212—1531
202251439559
20230—0691
20241—0603
202541864634
20261—0—

What is it indicated for?

The Surgitek Classic Double Pigtail Ureteral Stent is an indwelling device used to provide drainage from the kidney to the bladder and stenting of the ureter without external catheters. The stent may be placed using endoscopic, percutaneous or open procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K960148: Circon-Surgitek Classic Double Pigtail Ureteral Stent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K960148

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026