510(k) · Cleared
Cleared3I STND Threaded/Self Tapping Threaded/3I Miniplant Implants/3 I Emergence Prof. Temp. Healing Abutments
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Implant Innovations, Inc. · DZE Implant, Endosseous, Root-Form
Cleared on Aug 1, 1996 after a 185-day review. The FDA summary names its predicate without a number. 1,047 later devices descend from it.
- Decided
- Aug 1, 1996
- Review
- 185 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 0
1,047 later devices descend from it, 4 citing it directly.
- This deviceK960417 3I STND Threaded/Self Tapping Threaded/3I Miniplant Implants/3 I…Implant Innovations, Inc. · 1996
- Descendant · cites it directly · 1,043 of its ownK984104 Iti Dental Implant SystemStraumann USA · 1999 · Recalled
- Descendant · 2 generations on · 942 of its ownK993595 Nobel Biocare's Modified Surface Implant (Intended for Immediate…Nobel Biocare Uas, Inc. · 2000
- Descendant · 2 generations on · 735 of its ownK992937 Dental ImplantNobel Biocare Uas, Inc. · 2000 · Recalled
- Descendant · 3 generations on · 689 of its ownK023113 Replace Tiunite Endosseous ImplantNobel Biocare Uas, Inc. · 2002 · Recalled
- Descendant · 4 generations on · 622 of its ownK041661 Nobel Biocare Endosseous ImplantsNobel Biocare Uas, Inc. · 2004
Showing 5 of 1,047 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 1,047 · See all- K984104Iti Dental Implant SystemStraumann USA · 1999 · cites it directly1,043descendants
- K993595Nobel Biocare's Modified Surface Implant (Intended for Immediate Loading Upon Placement)Nobel Biocare Uas, Inc. · 2000 · 2 generations on942descendants
- K992937Dental ImplantNobel Biocare Uas, Inc. · 2000 · 2 generations on735descendants
- K023113Replace Tiunite Endosseous ImplantNobel Biocare Uas, Inc. · 2002 · 3 generations on689descendants
- K041661Nobel Biocare Endosseous ImplantsNobel Biocare Uas, Inc. · 2004 · 4 generations on622descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K960417 | 3I STND Threaded/Self Tapping Threaded/3I Miniplant Implants/3 I Emergence… | Implant Innovations, Inc. | 1996 | — |
| +1 | K984104 | Iti Dental Implant System | Straumann USA | 1999 | 1 |
| +2 | K993595 | Nobel Biocare's Modified Surface Implant (Intended for Immediate Loading Upon… | Nobel Biocare Uas, Inc. | 2000 | — |
| +2 | K992937 | Dental Implant | Nobel Biocare Uas, Inc. | 2000 | 1 |
| +3 | K023113 | Replace Tiunite Endosseous Implant | Nobel Biocare Uas, Inc. | 2002 | 27 |
| +4 | K041661 | Nobel Biocare Endosseous Implants | Nobel Biocare Uas, Inc. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 2 | 0 |
| 2000 | 3 | 0 |
| 2001 | 2 | 0 |
| 2002 | 6 | 0 |
| 2003 | 8 | 0 |
| 2004 | 13 | 0 |
| 2005 | 15 | 0 |
| 2006 | 22 | 0 |
| 2007 | 25 | 0 |
| 2008 | 37 | 0 |
| 2009 | 32 | 0 |
| 2010 | 27 | 0 |
| 2011 | 38 | 0 |
| 2012 | 39 | 0 |
| 2013 | 54 | 0 |
| 2014 | 48 | 0 |
| 2015 | 48 | 0 |
| 2016 | 52 | 0 |
| 2017 | 49 | 0 |
| 2018 | 49 | 0 |
| 2019 | 41 | 0 |
| 2020 | 73 | 0 |
| 2021 | 55 | 0 |
| 2022 | 60 | 0 |
| 2023 | 74 | 0 |
| 2024 | 77 | 0 |
| 2025 | 65 | 0 |
| 2026 | 33 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Non-Submerged Implant System Named without a submission number | |
| * | — | Immediate-Load Implant Named without a submission number |
What descends from it? (1,047)
See all 1,0474 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K984104 (Straumann USA, 1999) has gone furthest, with 1,043 descendants of its own.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
A single-stage surgical process by which a 3i implant is placed into the bone and a 1 or 2 piece (EP) Temporary Healing Abutment is immediately attached to the implant, may be considered in those cases where the implant and healing abutment can be adequately protected from mastication forces throughout the healing period, by opposing dentition, denture or bridge that if required, may be modified to provide such protection.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K960417 · printed Nov 4, 2026
Cite this page
510(k) Report. “K960417: 3I STND Threaded/Self Tapping Threaded/3I Miniplant Implants/3 I Emergence Prof. Temp. Healing Abutments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K960417
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026