510(k) Report

510(k) · Cleared

Recalled · Class I · 2026

Arrow Bipolar Pacing/Balloon Wedge Pressure Catheter

K960479510(k) TraditionalCleared Oct 17, 1996258-day reviewClass II21 CFR 870.3680Recalls 4 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Arrow Intl., Inc. · LDF Electrode, Pacemaker, Temporary

Cleared on Oct 17, 1996 as substantially equivalent to K832850 (Electro-Catheter Corp., 1983) and 1 other predicate after a 258-day review. Its family tree reaches back 1 generation to 1983. 1 of the 3 devices in its family, counting itself, has a Class I recall. It has been recalled 4 times, including a Class I recall.

Decided
Oct 17, 1996
Review
258 days
Class
Class II
Product code
LDF
Recalls
4 (1 Class I)
Predicates
2

Its longest line of descent runs back 1 generation to K832850 (1983). 2 ancestors in all. No later device cites it as a predicate yet. 1 of the 3 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 1984: 1 other ancestorK832850 · Elecath Pacewedge Dual Press. Bipolar · Electro-Catheter Corp. · 19831980198519901995
Other ancestors, by generation 1 generation back: 1 other ancestor K832850 · Elecath Pacewedge Dual Press. Bipolar · Electro-Catheter Corp. · 19830
  1. Root · 1 generation backK832850 Elecath Pacewedge Dual Press. BipolarElectro-Catheter Corp. · 1983
  2. This deviceK960479 Arrow Bipolar Pacing/Balloon Wedge Pressure CatheterArrow Intl., Inc. · 1996
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K832850Elecath Pacewedge Dual Press. BipolarElectro-Catheter Corp.1983—
0 (this device)K960479Arrow Bipolar Pacing/Balloon Wedge Pressure CatheterArrow Intl., Inc.1996—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198410
FIG. 1 — Lineage of K960479, 1983–1996Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LDF device

  1. #1 K241334 Semi-Floating Temporary Pacing Electrode…score 12.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K832850Elecath Pacewedge Dual Press. Bipolar
Summary page 1
…ecath® Ventricular Pacewedge® Pacing and Pressure Catheter, open tip, 996 catalog no. 34-6567, from the Electro-Catheter Corporation, Rahway, NJ, Premarket Notifications K832850 and K844003. 2. A combination of two Arrow pre-enactment catheters, the Balloon Temporary Bipolar Pacing Catheter and the Balloo…
Electro-Catheter Corp.1983—
*K844003Elecath Ventricular Pacing Wedge Pressure Cath
Summary page 1
…icular Pacewedge® Pacing and Pressure Catheter, open tip, 996 catalog no. 34-6567, from the Electro-Catheter Corporation, Rahway, NJ, Premarket Notifications K832850 and K844003. 2. A combination of two Arrow pre-enactment catheters, the Balloon Temporary Bipolar Pacing Catheter and the Balloon Wedge Pres…
Electro-Catheter Corp.1984—
*—Balloon Temporary Bipolar Pacing Catheter
Named without a submission number
—
*—Balloon Wedge Pressure catheter
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 21, 2026Class IZ-2383-2026Nonconforming Material/ComponentLidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a…
Feb 11, 2009Not classifiedZ-1500-2009Device DesignLeakage: Material not lipid resistant, may crack and/or leak. Use of this device with lipid containing solutions or 70% isopropyl alcohol may cause leakage or air embolism.
Apr 1, 2008Not classifiedZ-1908-2008Process controlThe 5 Fr. (110cm) Temporary Pacing Catheter/ 6 Fr. Introducer Kits do not contain a complete 6 Fr. Introducer Assembly.
Apr 1, 2008Not classifiedZ-1907-2008Process controlThe 5 Fr. (110cm) Temporary Pacing Catheter/ 6 Fr. Introducer Kits do not contain a complete 6 Fr. Introducer Assembly.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.

How does its category compare?

All LDF devices

LDF Electrode, Pacemaker, Temporary: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LDF

5in 2025

2008: 12014: 12015: 22016: 32017: 12018: 12019: 12024: 12025: 52026 (partial year): 1
2007high 5 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LDF

266in 2025

2016: 138 days median2025: 266 days median
2007high 266 (2025) · low 138 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LDF

1in 2018

2008: 22009: 22011: 12012: 12018: 1, 1 Class I2026 (partial year): 1, 1 Class I
2007high 2 (2008) · low 0 (2007)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · LDF

139in 2025

2007: 252008: 182009: 442010: 482011: 352012: 682013: 742014: 682015: 812016: 902017: 792018: 912019: 1302020: 832021: 1252022: 1172023: 2122024: 1902025: 139
2007high 212 (2023) · low 18 (2008)2025

MAUDE reports naming product code LDF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—025
20081—218
20090—244
20100—048
20110—135
20120—168
20130—074
20141—068
20152—081
20163138090
20171—079
20181—1 (1)91
20191—0130
20200—083
20210—0125
20220—0117
20230—0212
20241—0190
202552660139
20261—1 (1)—

What is it indicated for?

The ARROW catheter is indicated for use in sampling blood for oxygen levels and measuring pressure in the right heart (including central venous pressure, right ventricular pressure, pulmonary artery pressure, and pulmonary artery wedge pressure). The second pressure lumen allows infusion of a solution with simultaneous measurement of pressure. The catheter is intended for temporary use in electrophysiology studies for intracardiac simulation and/or ECG recording only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K960479: Arrow Bipolar Pacing/Balloon Wedge Pressure Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K960479

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026