510(k) Report

510(k) · Cleared

Cleared

MICRO21 with Retic

K960776510(k) TraditionalCleared May 17, 199681-day reviewClass II21 CFR 864.5260

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Triangle Biomedical Sciences, Inc. · JOY Device, Automated Cell-Locating

Cleared on May 17, 1996 as substantially equivalent to K925670 (Intelligent Medica Imaging, Inc., 1993) after an 81-day review. Its family tree reaches back 1 generation to 1993.

Decided
May 17, 1996
Review
81 days
Class
Class II
Product code
JOY
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K925670 (1993). No later device cites it as a predicate yet.

K925670 · IMS-200 · Intelligent Medica Imaging, Inc. · 199319901992199419961998
K925670 · IMS-200 · Intelligent Medica Imaging, Inc. · 19930
  1. Root · 1 generation backK925670 IMS-200Intelligent Medica Imaging, Inc. · 1993
  2. This deviceK960776 MICRO21 with ReticTriangle Biomedical Sciences, Inc. · 1996
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K925670IMS-200Intelligent Medica Imaging, Inc.1993—
0 (this device)K960776MICRO21 with ReticTriangle Biomedical Sciences, Inc.1996—
FIG. 1 — Lineage of K960776, 1993–1996Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JOY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JOY device

  1. #1 K243144 X100/X100HT with Full Field Peripheral Blood…score 11.1 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K925670IMS-200
Summary page 1
…: Automated Cell Locating Device Classification Number: 81JOY Class: I Regulation Number: 864.5260 The MICRO2I™ with WBC Diff (White Blood Cell Differential) Ref. No. K925670/A is an automated microscopic system that locates WBCs, stores digital images of the cells and displays the images in an organize…
Intelligent Medica Imaging, Inc.1993—

Also cleared against K925670: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 4 other devices also cite its predicate K925670.

How does its category compare?

All JOY devices

JOY Device, Automated Cell-Locating: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JOY

1in 2025

2007: 32008: 12009: 12010: 12011: 12017: 12018: 12020: 22022: 12023: 12025: 1
2007high 3 (2007) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JOY

136in 2007

2007: 136 days median
2007high 136 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JOY

1in 2025

2025: 1
2007high 1 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JOY

1in 2025

2017: 42019: 32022: 22024: 52025: 1
2007high 5 (2024) · low 0 (2007)2025

MAUDE reports naming product code JOY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007313600
20081—00
20091—00
20101—00
20111—00
20120—00
20130—00
20140—00
20150—00
20160—00
20171—04
20181—00
20190—03
20202—00
20210—00
20221—02
20231—00
20240—05
20251—11
20260—0—

What is it indicated for?

The MICRO21 with Retic is a new MICRO21 intended use that follows the same process as the MICRO21 with WBC Diff, but instead locates, digitally stores and displays reticulated red blood cells (retics) to aid the technologist in performing the Reticulocyte Count procedure.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K960776: MICRO21 with Retic.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K960776

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026