510(k) Report

510(k) · Cleared

Cleared

Cytoquant Chlamydia Transport Medium

K961755510(k) TraditionalCleared May 17, 199611-day reviewClass I21 CFR 866.2390

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Proteins Intl., Inc. · JSN Culture Media, Propagating Transport

Cleared on May 17, 1996 after an 11-day review. The FDA summary names no predicate by number.

Decided
May 17, 1996
Review
11 days
Class
Class I
Product code
JSN
Recalls
None
Predicates
0

The FDA summary names no predicate by number.

FIG. 1 — Lineage of K961755Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JSN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All JSN devices

JSN Culture Media, Propagating Transport: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JSN

FDA has decided no JSN device since 2007.

Median 510(k) review, days · JSN

Too few JSN 510(k)s in any year since 2007 to give a median.

Recalls per year · JSN

No recall names JSN since 2007.

Adverse event reports per year · JSN

No MAUDE report names JSN since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—
Cite this page

510(k) Report. “K961755: Cytoquant Chlamydia Transport Medium.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K961755

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026