510(k) Report

510(k) · Cleared

Cleared

WLP Single-Segment Version WLP Solo Vii

K961891510(k) TraditionalCleared Nov 6, 1996181-day reviewClass II21 CFR 870.5800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wright Linear Pump, Inc. · JOW Sleeve, Limb, Compressible

Cleared on Nov 6, 1996 as substantially equivalent to K874688 (Huntleigh Technology, Inc., 1988) and 1 other predicate after a 181-day review. Its family tree reaches back 1 generation to 1988.

Decided
Nov 6, 1996
Review
181 days
Class
Class II
Product code
JOW
Recalls
None
Predicates
3

Its longest line of descent runs back 1 generation to K882683 (1988). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1988: 1 other ancestorK882683 · Jobst Extremity Pump (R) System 7500 · Jobst Institute, Inc. · 19881986198819901992199419961998
Other ancestors, by generation 1 generation back: 1 other ancestor K882683 · Jobst Extremity Pump (R) System 7500 · Jobst Institute, Inc. · 19880
  1. Root · 1 generation backK882683 Jobst Extremity Pump (R) System 7500Jobst Institute, Inc. · 1988
  2. This deviceK961891 WLP Single-Segment Version WLP Solo ViiWright Linear Pump, Inc. · 1996
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K882683Jobst Extremity Pump (R) System 7500Jobst Institute, Inc.1988—
0 (this device)K961891WLP Single-Segment Version WLP Solo ViiWright Linear Pump, Inc.1996—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
FIG. 1 — Lineage of K961891, 1988–1996Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JOW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JOW device

  1. #1 K253555 Flexitouch® Plus Advanced Pneumatic…score 14.8 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K874688Flowtron AC200/2
Summary page 1
…............... 74JOW 5.3. equivalence 5.3.1. The proposed device is similar in design, function, and composition to existing compression pump devices such as document K874688 Huntleigh Flowtron AC200/2, document K882683 Jobst Extremity Pump System 7000, and document K814775 Talley MicroSystem/Talley. 5…
Huntleigh Technology, Inc.1988—
*K882683Jobst Extremity Pump (R) System 7500
Summary page 1
…1. The proposed device is similar in design, function, and composition to existing compression pump devices such as document K874688 Huntleigh Flowtron AC200/2, document K882683 Jobst Extremity Pump System 7000, and document K814775 Talley MicroSystem/Talley. 5.3.1.1. As a single pressure system, the prop…
Jobst Institute, Inc.1988—
Kept off the family treeK814775Talley MicroSystem/Talley
Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree
Summary page 1
…and composition to existing compression pump devices such as document K874688 Huntleigh Flowtron AC200/2, document K882683 Jobst Extremity Pump System 7000, and document K814775 Talley MicroSystem/Talley. 5.3.1.1. As a single pressure system, the proposed device is simpler than existing sequential pressur…

Also cleared against K874688: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K874688.

How does its category compare?

All JOW devices

JOW Sleeve, Limb, Compressible: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JOW

7in 2025

2007: 62008: 42009: 32010: 182011: 112012: 132013: 172014: 162015: 102016: 92017: 92018: 112019: 112020: 142021: 162022: 72023: 62024: 82025: 72026 (partial year): 6
2007high 18 (2010) · low 3 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JOW

168in 2025

2007: 66 days median2008: 112 days median2009: 84 days median2010: 71 days median2011: 104 days median2012: 63 days median2013: 94 days median2014: 91 days median2015: 160 days median2016: 121 days median2017: 116 days median2018: 136 days median2019: 88 days median2020: 158 days median2021: 132 days median2022: 80 days median2023: 160 days median2024: 197 days median2025: 168 days median2026 (partial year): 252 days median
2007high 252 (2026) · low 63 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JOW

1in 2019

2008: 72010: 22011: 32012: 22017: 12019: 1
2007high 7 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JOW

24in 2025

2007: 122008: 362009: 452010: 662011: 502012: 1002013: 1692014: 932015: 1372016: 1502017: 1492018: 1142019: 1022020: 502021: 342022: 272023: 572024: 302025: 24
2007high 169 (2013) · low 12 (2007)2025

MAUDE reports naming product code JOW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007666012
20084112736
2009384045
20101871266
201111104350
201213632100
201317940169
20141691093
2015101600137
201691210150
201791161149
2018111360114
201911881102
202014158050
202116132034
2022780027
20236160057
20248197030
20257168024
202662520—

What is it indicated for?

The proposed device is to be used to improve the return circulation of body fluid that has pooled in one or more of a patient's extremities. This treatment reduces debilitating pain, swelling, ulceration, and risk of dermatological impact, infection, and amputation.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K961891: WLP Single-Segment Version WLP Solo Vii.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K961891

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026