Continuous Flush Device

K962129510(k) TraditionalCleared Apr 15, 1997316-day reviewClass II21 CFR 870.1210

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Merit Medical Systems, Inc. · KRA Catheter, Continuous Flush

Cleared on Apr 15, 1997 as substantially equivalent to K873168 (Spectramed, Inc., 1988) and 1 other predicate after a 316-day review. Its family tree reaches back 1 generation to 1979.

Decided
Apr 15, 1997
Review
316 days
Class
Class II
Product code
KRA
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K792141 (1979). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1988: 1 other ancestorK792141 · Continuous Flush Device · Pharmaseal Div., Baxter Healthcare Corp. · 197919751980198519901995
Other ancestors, by generation 1 generation back: 1 other ancestor K792141 · Continuous Flush Device · Pharmaseal Div., Baxter Healthcare Corp. · 19790
  1. Root · 1 generation backK792141 Continuous Flush DevicePharmaseal Div., Baxter Healthcare Corp. · 1979
  2. This deviceK962129 Continuous Flush DeviceMerit Medical Systems, Inc. · 1997
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K792141Continuous Flush DevicePharmaseal Div., Baxter Healthcare Corp.1979—
0 (this device)K962129Continuous Flush DeviceMerit Medical Systems, Inc.1997—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
FIG. 1 — Lineage of K962129, 1979–1997Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KRA device

  1. #1 K253509 TriSalus TriNav Advance Infusion Systemscore 14.4 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K873168Spectramed Disposable Transducer (DT-Xxo) & Access
Summary page 1
…al Care Division Edwards Critical Care Division 1900 Williams Bivd 17221 Red Hill Avenue FAx 801-253-1651 Oxnard, CA 93030 Irvine, CA 92714 (800) 235-5945 (800) 424-3278 K873168 K792141 INDICATIONS FOR USE A continuous flush device is an accessory to a catheter-transducer system that permits a continuous…
Spectramed, Inc.1988—
*K792141Continuous Flush Device
Summary page 1
…Division Edwards Critical Care Division 1900 Williams Bivd 17221 Red Hill Avenue FAx 801-253-1651 Oxnard, CA 93030 Irvine, CA 92714 (800) 235-5945 (800) 424-3278 K873168 K792141 INDICATIONS FOR USE A continuous flush device is an accessory to a catheter-transducer system that permits a continuous flow to…
Pharmaseal Div., Baxter Healthcare Corp.1979—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.

How does its category compare?

All KRA devices

KRA Catheter, Continuous Flush: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KRA

1in 2025

2007: 52008: 72009: 52010: 22011: 22012: 32013: 32014: 42016: 82017: 42018: 42019: 42020: 62021: 62022: 62023: 72025: 12026 (partial year): 5
2007high 8 (2016) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KRA

63in 2023

2007: 44 days median2008: 144 days median2009: 69 days median2012: 29 days median2013: 126 days median2014: 61 days median2016: 122 days median2017: 166 days median2018: 178 days median2019: 133 days median2020: 29 days median2021: 108 days median2022: 228 days median2023: 63 days median2026 (partial year): 268 days median
2007high 268 (2026) · low 29 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KRA

41so far in 2026, the most since 2007

2007: 22008: 62009: 82010: 262011: 32012: 32013: 22014: 3, 2 Class I2015: 12016: 3, 1 Class I2019: 4, 4 Class I2020: 12023: 22026 (partial year): 41
2007high 41 (2026) · low 0 (2017)2026

Class I (7 since 2007) Class II/III not classified

Adverse event reports per year · KRA

980in 2025

2007: 1182008: 1172009: 1872010: 3552011: 2392012: 2172013: 2092014: 2762015: 3392016: 4182017: 5382018: 4342019: 4182020: 3812021: 4402022: 5432023: 8292024: 9422025: 980
2007high 980 (2025) · low 117 (2008)2025

MAUDE reports naming product code KRA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075442118
200871446117
20095698187
20102—26355
20112—3239
20123293217
201331262209
20144613 (2)276
20150—1339
201681223 (1)418
201741660538
201841780434
201941334 (4)418
20206291381
202161080440
202262280543
20237632829
20240—0942
20251—0980
2026526841—

What is it indicated for?

A continuous flush device is an accessory to a catheter-transducer system that permits a continuous flow to maintain catheter patency.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K962129: Continuous Flush Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K962129

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026