510(k) Report

510(k) · Cleared

Cleared

Ventricular Catheter Blood Flow Monitoring Probe Kit and Ventraflo Blood Flow Monitoring Probe Kit

K962700510(k) TraditionalCleared Apr 9, 1997271-day reviewClass II21 CFR 870.2120

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vasamedics, LLC · DPT Probe, Blood-Flow, Extravascular

Cleared on Apr 9, 1997 as substantially equivalent to K951832 (Vasamedics, LLC, 1996) after a 271-day review. Its family tree reaches back 2 generations to 1988. 1 later device descends from it.

Decided
Apr 9, 1997
Review
271 days
Class
Class II
Product code
DPT
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K875179 (1988). 3 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 1 descendant K951832 · Laserflo Blood Perfusion Single Use Probes Models Sup-440, Supr-434 Sup-433 · Vasamedics, LLC · 1996K875179 · Modified Laserflo Blood Perfusion Monitor, BPM403A · Tsi, Inc. · 19880
  1. Root · 2 generations backK875179 Modified Laserflo Blood Perfusion Monitor, BPM403ATsi, Inc. · 1988
  2. 1 generation backK951832 Laserflo Blood Perfusion Single Use Probes Models Sup-440, Supr-434…Vasamedics, LLC · 1996
  3. This deviceK962700 Ventricular Catheter Blood Flow Monitoring Probe Kit and Ventraflo…Vasamedics, LLC · 1997
  4. Descendant · cites it directly · 0 of its ownK013376 Qflow 500 Perfusion Monitoring SystemHemedex Incorporated · 2002

Most influential descendants

Showing 1 of 1 · See all
  • K013376Qflow 500 Perfusion Monitoring SystemHemedex Incorporated · 2002 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K875179Modified Laserflo Blood Perfusion Monitor, BPM403ATsi, Inc.1988—
−1K951832Laserflo Blood Perfusion Single Use Probes Models Sup-440, Supr-434 Sup-433Vasamedics, LLC1996—
0 (this device)K962700Ventricular Catheter Blood Flow Monitoring Probe Kit and Ventraflo Blood Flow…Vasamedics, LLC1997—
+1K013376Qflow 500 Perfusion Monitoring SystemHemedex Incorporated2002—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
FIG. 1 — Lineage of K962700, 1988–2002Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DPT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DPT device

  1. #1 K233076 Laser Speckle Imaging System (RFLSI CZW)score 8.6 · 5 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K951832Laserflo Blood Perfusion Single Use Probes Models Sup-440, Supr-434 Sup-433
Summary page 1
…ally equivalent to products currently in commercial distribution. Specifically, for the laser Doppler Probe the Vasamedics® model SUPR-434 Single use Blunt Needle Probe, K951832, for kit accessories and ventricular catheter the PS Medical “Becker Ventricular Catheter” and the “PS Medical Ventriculostomy Ki…
Vasamedics, LLC1996—
*—PS Medical “Becker Ventricular Catheter”
Named without a submission number
—
*—PS Medical “Ventriculostomy Kit”
Named without a submission number
—
†K896515Laserflo Blood Perfusion Monitor, Model BPM2Tsi, Inc.1990—

Also cleared against K951832: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K013376Qflow 500 Perfusion Monitoring SystemHemedex Incorporated20020

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 7.5 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K013376 (Hemedex Incorporated, 2002) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K951832.

How does its category compare?

All DPT devices

DPT Probe, Blood-Flow, Extravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DPT

1in 2024

2007: 32009: 12012: 22013: 32014: 32015: 12016: 12017: 12024: 1
2007high 3 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DPT

201in 2014

2007: 55 days median2013: 108 days median2014: 201 days median
2007high 201 (2014) · low 55 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DPT

22in 2024

2024: 22
2007high 22 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DPT

52in 2025

2007: 52008: 12009: 32010: 32011: 32012: 12014: 52018: 32019: 12020: 32021: 132022: 462023: 212024: 1692025: 52
2007high 169 (2024) · low 0 (2013)2025

MAUDE reports naming product code DPT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735505
20080—01
20091—03
20100—03
20110—03
20122—01
2013310800
2014320105
20151—00
20161—00
20171—00
20180—03
20190—01
20200—03
20210—013
20220—046
20230—021
20241—22169
20250—052
20260—0—

What is it indicated for?

The probes kits are intended for extravascular monitoring of microcirculation blood flow in buried tissues, specifically, in monitoring cerebral blood flow in patients at risk of cerebral ischemia.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K962700: Ventricular Catheter Blood Flow Monitoring Probe Kit and Ventraflo Blood Flow Monitoring Probe Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K962700

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026