510(k) Report

510(k) · Cleared

Cleared

Clinidyne Rotational Therapy Mattress System

K962788510(k) TraditionalCleared Apr 30, 1997287-day reviewClass II21 CFR 890.5225

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Gaymar Industries, Inc. · IKZ Bed, Patient Rotation, Powered

Cleared on Apr 30, 1997 after a 287-day review. The FDA summary names its predicate without a number.

Decided
Apr 30, 1997
Review
287 days
Class
Class II
Product code
IKZ
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K962788Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IKZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—CLA 1400 System
Named without a submission number
—
*—CLD-1000
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All IKZ devices

IKZ Bed, Patient Rotation, Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IKZ

FDA has decided no IKZ device since 2007.

Median 510(k) review, days · IKZ

Too few IKZ 510(k)s in any year since 2007 to give a median.

Recalls per year · IKZ

1in 2021

2010: 12011: 12013: 12018: 12021: 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IKZ

12in 2025

2007: 72008: 42009: 112010: 262011: 482012: 692013: 2942014: 802015: 402016: 262017: 352018: 282019: 272020: 292021: 112022: 62023: 202024: 72025: 12
2007high 294 (2013) · low 4 (2008)2025

MAUDE reports naming product code IKZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—07
20080—04
20090—011
20100—126
20110—148
20120—069
20130—1294
20140—080
20150—040
20160—026
20170—035
20180—128
20190—027
20200—029
20210—111
20220—06
20230—020
20240—07
20250—012
20260—0—

What is it indicated for?

The CLINI-DYNE rotational/low air loss system is a patient rotation, pressure relieving support system used for the treatment and prevention of decubitus ulcers, urinary tract blockage, to aid circulation and for complications associated with immobility.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K962788: Clinidyne Rotational Therapy Mattress System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K962788

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026