510(k) · Cleared
ClearedHans Rudolph Nasal Cpap Mask
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Hans Rudolph, Inc. · BYG Mask, Oxygen
Cleared on Oct 16, 1996 after an 86-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 3 later devices descend from it.
- Decided
- Oct 16, 1996
- Review
- 86 days
- Class
- Class I
- Product code
- BYG
- Recalls
- None
- Predicates
- 0
3 later devices descend from it, 1 citing it directly.
- This deviceK962848 Hans Rudolph Nasal Cpap MaskHans Rudolph, Inc. · 1996
- Descendant · cites it directly · 2 of its ownK984254 Infant Flow Ncpap MasksSensor Medics Corp. · 1999
- Descendant · 2 generations on · 0 of its ownK030563 Arabella Ncpap MasksHamilton Medical AG · 2003
- Descendant · 2 generations on · 0 of its ownK012034 Modification to: Sipap Infant Nasal Cpap CircuitSensor Medics Corp. · 2001
Most influential descendants
Showing 3 of 3 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K962848 | Hans Rudolph Nasal Cpap Mask | Hans Rudolph, Inc. | 1996 | — |
| +1 | K984254 | Infant Flow Ncpap Masks | Sensor Medics Corp. | 1999 | — |
| +2 | K030563 | Arabella Ncpap Masks | Hamilton Medical AG | 2003 | — |
| +2 | K012034 | Modification to: Sipap Infant Nasal Cpap Circuit | Sensor Medics Corp. | 2001 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
| 2001 | 1 | 0 |
| 2003 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in BYG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it? (3)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K984254 | Infant Flow Ncpap Masks | 1999 | 2 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K984254 (Sensor Medics Corp., 1999) has gone furthest, with 2 descendants of its own.
How does its category compare?
All BYG devicesBYG Mask, Oxygen: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · BYG
FDA has decided no BYG device since 2007.
Median 510(k) review, days · BYG
Too few BYG 510(k)s in any year since 2007 to give a median.
Recalls per year · BYG
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · BYG
23in 2025
MAUDE reports naming product code BYG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 17 |
| 2008 | 0 | — | 0 | 16 |
| 2009 | 0 | — | 0 | 14 |
| 2010 | 0 | — | 0 | 13 |
| 2011 | 0 | — | 19 | 16 |
| 2012 | 0 | — | 0 | 19 |
| 2013 | 0 | — | 0 | 20 |
| 2014 | 0 | — | 0 | 51 |
| 2015 | 0 | — | 0 | 63 |
| 2016 | 0 | — | 0 | 22 |
| 2017 | 0 | — | 1 | 8 |
| 2018 | 0 | — | 1 | 39 |
| 2019 | 0 | — | 0 | 29 |
| 2020 | 0 | — | 0 | 6 |
| 2021 | 0 | — | 0 | 12 |
| 2022 | 0 | — | 0 | 18 |
| 2023 | 0 | — | 0 | 4 |
| 2024 | 0 | — | 0 | 9 |
| 2025 | 0 | — | 1 | 23 |
| 2026 | 0 | — | 0 | — |
https://510kreport.com/device/K962848 · printed Nov 4, 2026
Cite this page
510(k) Report. “K962848: Hans Rudolph Nasal Cpap Mask.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K962848
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026